Specifications
To find the latest version of the product's datasheet, go to the product page on axis.com and
locate Support & Documentation.
LED Indicators
There are two colored LED indicators on the base of the illuminator which provide operating and
status information. The color status depends on the current operating mode
There are two types of modes:
•
Programming Mode
•
Normal Operating Mode
On powering up, the illuminator will automatically enter Programming Mode.
For more information about the LED indicators and the different modes, see the User Manual
available at www.axis.com
•
LHS LED solid green = Power on
•
RHS LED flashing amber = Illuminator is in Programming Mode
•
LHS LED solid red = Illuminator fault detected
•
LHS LED flashing red = Voltage supply problem detected
Note
If any manual buttons are pressed, the illuminator automatically enters
Normal Operating Mode 30 minutes after the last button press.
After 7 days the illuminator automatically enters Normal Operating Mode and the RHS
LED is unlit.
Buttons
For information about the remote control and the two manual control buttons, see the User
Manual available at www.axis.com
Connectors
Power Connector
•
AC/DC power connector
•
Network cable
The external cable cannot be replaced. If it is damaged and the customer is unable to shorten and
re-use the cable, the illuminator must not be powered.
AXIS T90D Illuminators
17