Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

3 3
/ /
4 4
" "
3 3
/ /
4 4
" "
INSTRUCTION MANUAL
Catalog No. SF100
For any technical support, or customer
serviceon this product please call our
tech support or customer service team
at 877.312.4547 (EST) or send us
an email at info@solidsignal.com
www.solidsignal.com
SAVE THIS MANUAL FOR FUTURE REFERENCE.
VEA EL ESPAÑOL EN LA CONTRAPORTADA.
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA.
ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
Cat No. SF100 Form # 616706-00 (APR-03-1) Copyright © 2003 Black & Decker Printed in China
WARNING: To reduce the risk of injury, user must read and understand instruction
manual.
SAVE THESE INSTRUCTIONS
Safety Instructions
• Do not operate the stud sensor in explosive atmospheres, such as in the presence of
flammable liquids, gases, or dust.
• Use the stud sensor only with the specifically designated batteries. Use of any other
batteries may create a risk of fire.
Operating Instructions
CAUTION: Use caution when drilling, nailing or cutting into walls, floors and ceilings which
may contain electrical wiring or pipes. These items may be detected by the Stud Finder in
the same manner in which studs are detected. Because studs are normally spaced 16
inches or 24 inches apart and are 1-1/2 inches wide, beware of anything closer together or
of a different width. Always turn off the power when working near electrical wires.
INSTALLING THE BATTERY
Remove the battery compartment cover (D) by pressing down in the center of the cover and
pulling back. Insert two fresh AA batteries making sure to match (+) and (-) terminals
correctly. Replace the battery compartment cover.
CALIBRATION AND SCANNING
1.) Hold unit straight up and down and place flat against wall as shown in Figure 2.
2.) Press in and hold the stud sensor ON/OFF button (C).
a.) The upper red LED (A) will light,
b.) The unit will beep once while it is calibrating,
c.) The bottom green LED (B) will light.
3.) Slide sensor slowly, (Figure 3,) horizontally across surface of wall without lifting or tilting.
4.) The upper red LED will light and a beeper will sound when an edge is detected , mark
that spot (Figure 4).
Repeat this cycle coming from the other direction and again mark the spot where the upper
red LED lights and beeper sounds.
Measure between the two marks made on the wall and the center will coincide with the
center of the stud.
TIPS FOR OPTIMUM USE
• Test batteries before each use. Press and hold the on/off switch until the green LED lights.
Then move your free hand toward the back of the unit. The red light should illuminate and
then go out as you move your hand away from the unit. Replace the batteries if the red LED
does not illuminate.
• Hold stud sensor straight up and down.
• Because studs are normally spaced 16 inches or 24 inches apart and are 1-1/2 inches
wide, beware of anything closer together or of a different width. Doors and windows are
constructed with studs and headers which are closer together.
• Metal or wood studs can be detected through up to 3/4" drywall.
• Avoid materials which have inconsistent density such as:
• Carpeting and padding
• Ceramic floor tile
• Wallpaper containing metallic foils or fibers. Generally, surfaces covered with regular
wallpaper or fabric will scan with no difference in function.
• Walls that are freshly painted and are still damp.
• Excessively thick plaster and lath.
Maintenance
Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool;
never immerse any part of the tool into a liquid.
IMPORTANT: To assure product SAFETY and RELIABILITY, repairs, maintenance and
adjustment (other than those listed in this manual) should be performed by authorized
service centers or other qualified service personnel, always using identical replacement
parts.
WARNING:
The use of any accessory not recommended for use with this tool could
be hazardous.
S S
t t
u u
d d
S S
e e
n n
s s
o o
r r
S S
t t
u u
d d
S S
e e
n n
s s
o o
r r
1
C
2
4
T T
R R
O O
U U
T T
R R
O O
U U
Problem
Possible Cause
• Weak battery.
• LEDs do not light.
• Nothing to detect in that
area.
• Check mode. May have
been calibrated over a
stud.
• LED lights and sound
• Wall thickness is over
stay on.
3/4 inch thick.
• Voltage of two AA
• Upper LED lights in RED
batteries has dropped
and sound stays on.
below 2.2 volts.
• Detects other objects
• LEDs light in too many
besides studs.
places.
• Electrical wiring and
metal or plastic pipes
may be near or touching
back surface of wall.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Service Information
All Black & Decker Service Centers are staffed with trained personnel to provide customers
with efficient and reliable power tool service. Whether you need technical advice, repair, or
genuine factory replacement parts, contact the Black & Decker location nearest you. To find
your local service location, refer to the yellow page directory under "Tools—Electric" or call:
1-800-544-6986.
Full Two-Year Home Use Warranty
Black & Decker (U.S.) Inc. warrants this product for two years against any defects in material
or workmanship. The defective product will be replaced or repaired at no charge in either of
two ways.
The first, which will result in exchanges only, is to return the product to the retailer from whom it
was purchased (provided that the store is a participating retailer). Returns should be made
within the time period of the retailer's policy for exchanges (usually 30 to 90 days after the
sale). Proof of purchase may be required. Please check with the retailer for their specific return
policy regarding returns that are beyond the time set for exchanges.
The second option is to take or send the product (prepaid) to a Black & Decker owned or
authorized Service Center for repair or replacement at our option. Proof of purchase may be
required. Black & Decker owned and authorized Service Centers are listed under "Tools-
Electric" in the yellow pages of the phone directory.
This warranty does not apply to accessories. This warranty gives you specific legal rights and
you may have other rights which vary from state to state. Should you have any questions,
contact the manager of your nearest Black & Decker Service Center.
This product is not intended for commercial use.
FEATURES
A.) Red LED (
Diode)
A
B.) Green LED
C.) On/Off Button
B
D.) Battery Compartment
Cover
D
3
B B
L L
E E
S S
H H
O O
O O
T T
I I
N N
G G
B B
L L
E E
S S
H H
O O
O O
T T
I I
N N
G G
Solution
• Replace with fresh batteries.
• Start again moving farther to either
side.
• Thickness must be less than 3/4
inch to calibrate and work properly.
• Replace with fresh batteries.
• Because studs are normally
spaced 16 inches or 24 inches apart
and are 1-1/2 inches wide, beware
of anything closer together or of a
different width.
Light Emitting

Publicidad

loading

Resumen de contenidos para Black and Decker SF100

  • Página 1 INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. Cat No. SF100 Form # 616706-00 (APR-03-1) Copyright © 2003 Black & Decker Printed in China WARNING: To reduce the risk of injury, user must read and understand instruction manual.
  • Página 2 • Recommencer le balayage en se aucun montant. déplaçant plus loin de chaque côté du montant. • L’outil a été étalonné No de catalogue SF100 au niveau d’un montant. Vérifier le mode de balayage. SI VOUS ÉPROUVEZ UN PROBLÈME AVEC L’OUTIL, •...
  • Página 3 CONSEJOS PARA SU USO ÓPTIMO • Pruebe las pilas cada vez que lo vaya a utilizar. Presione y sostenga el botón on/off hasta que el LED verde se ilumine. Luego, ponga la otra mano detrás del dispositivo. La luz roja debería iluminarse y luego apagarse cuando retire su mano del dispositivo.