Descargar Imprimir esta página

Maclean Energy MCE295 Guia De Inicio Rapido página 2

Publicidad

Installation Height: 1.8-2.5m wall /2.2-4m ceiling
Time Delay: Min.10sec±3sec
Detection Moving Speed: 0.6-1.5m/s
Max. 10min±3min
FUNCTION: Can identify day and night: The consumer can adjust working state in
different ambient light. It can work in the daytime and at night when it is adjusted on the
"sun" position (max). It can work in the ambient light less than 3LUX when it is adjusted
on the "moon" position (min). As for the adjustment pattern, please refer to the testing
pattern. • Time-Delay is added continually: When it receives the second induction
signals within the first induction, it will restart to time from the moment.
INSTALLATION: (see the diagram) • Shut off power. • Loosen the screw on the bottom
lid, open the wiring hole, pass the wire of power and load through the bottom lid.
• Fix the bottom lid with inflated screw on the selected position. • Connect the power
and load wire into connection-wire column according to the connecting figure.
• Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it.
CONNECTION-WIRE DIAGRAM: (See the right figure)
TEST: Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob
clockwise on the maximum (sun). • Switch on the power; the sensor and its connected
lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start
work .If the sensor receives the induction signal, the lamp will turn on. While there is no
another induction signal any more, the load should stop working within 10sec±3sec and
the lamp would turn off. • Turn LUX knob anti-clockwise on the minimum (-). If the
ambient light is more than 10LUX, the sensor would not work and the lamp stop working
too. If the ambient light is less than 10LUX (darkness), the sensor would work. Under no
induction signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
NOTES: This product should only be installed by qualified electrician.
This product should not be installed on an unstable surface.
Don't place any objects in front of the detection window as they will interfere with the
detection operation. Avoid installing it near air temperature alteration zones for example:
air conditioners, central heating, etc. For your safety. Please don't open this product
before switching off the power completely. In order to avoid the unexpected damage
of product, please add a safe device of 6A when installing infrared sensor, for example,
fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY:
The load does not work: a. Please check if the connection of power source and load
is correct. b. Please check if the load is good. c. Please check if the settings of working
light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals. b. Please check if the ambient temperature is too high. c. Please check if
the induction signal source is in the detection field. d. Please check if the installation
height corresponds to the height required in the instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field. b. Please check if the
time delay is set to the maximum position c. Please check if the power corresponds
to the instruction.
PL
Czujnik ruchu na podczerwień
Urządzenie to wykazuje wysoką czułość oraz posiada wbudowany układ scalony SMT.
Zapewnia automatykę, wygodę, bezpieczeństwo oraz oszczędność energii. Źródłem
sygnału włączającego urządzenie są promienie podczerwone wysyłane naturalnie przez
człowieka. W momencie gdy źródło sygnału znajdzie się w polu detekcji, urządzenie
włączy się po wcześniejszym automatycznym rozpoznaniu dnia oraz nocy.
Urządzenie jest łatwe w instalacji oraz może być szeroko zastosowane. Posiada
funkcje sygnalizacji zasilania i wykrywania.
SPECYFIKACJA:
Zasilanie: 220-240V/AC
Obszar detekcji: 180°+ 360°
Częstotliwość: 50/60Hz
Temperatura pracy: -20/+40°C
Czujnik oświetlenia:<10-2000LUX(regul.)
Wilgotność: <93% RH
FUNKCJE: Funkcja rozróżniania dnia oraz nocy: Użytkownik może dostosować pracę
urządzenia do światła otoczenia. Urządzenie pracuje zarówno w dzień jak i w nocy gdy
pokrętło jest ustawione w pozycji „+" (max). Urządzenie pracuje w świetle otoczenia
mniejszym niż 10 LUX gdy pokrętło jest ustawione w pozycji „-" (min).
W celu odpowiedniego ustawienia prosimy zapoznać się z sekcją „TEST".
- Opóźnienie czasowe: Po odebraniu drugiego sygnału indukcyjnego po pierwszym
sygnale, obliczy ono czas jeszcze raz na podstawie pierwszego opóźnienia.
Instalacja (patrz diagram): Wyłącz zasilanie. • Odkręć śruby w dolnej pokrywie, przez
otwór w dolnej części czujnika przeprowadź przewód zasilający. • Zamontuj pokrywę
i umocuj w wybranej pozycji za pomocą dołączonych śrub. • Podłącz przewód
zasilający do kolumny przyłączeniowej zgodnie z schematem połączeń. • Umieść
czujnik na dolnej pokrywie, mocno przekręć śrubę, a następnie włącz zasilanie
i przetestuj.
MCE295
Opóźnienie czasowe: min. 10sek +/- 3sek.
max. 10min. +/- 3min
Wys. instalacji: ściana:1.8-2.5m/ sufit 2.2-4m
Prędkość detekcji ruchu: 0.6~1.5m/s
Obciążenie max.
2000W
1000W
Dystans detekcji: max. 12m (<24°C)