CAUTION: Tipping the gas cylinder more than 60 degrees from its upright position may cause torch to flare. The torch has a built-in
regulator that controls pressure and reduces the risk of pulsating or yellow flames when used other than upright. It is recommended to start
working with a disposable hand torch cylinder at room temperature and to keep torch upright as much as possible.
1.
Open regulator valve fully by turning adjustment knob (1) counter clockwise until it stops. Do not force. Always fully open valve when
lighting to prevent damage to ignition system. Never look into the burner tube (3) or point in unsafe direction.
2.
Point torch in a safe direction and push the ignition button (2). Repeat if necessary while adjusting the valve (1) slightly.
3.
After the torch lights the ignition button may be released and the flame may be adjusted.
4.
To adjust flame, grasp the regulator with one hand and use the other hand to turn the adjustment knob (1) to the required setting.
5.
To adjust the flame direction, grasp the case (4) and rotate burn tube (3) to desired position.
ADDITIONAL WARNINGS
•
Make sure the torch is cool before installing or removing cylinder and accessories. Using the torch with a low flame can cause damage
to the burn tube and ignition system.
•
Check all joints and couplings periodically to insure against loose connections. With valve open, without lighting, test all connections
with soapy water. If bubbles appear, gas is leaking and torch must be repaired or replaced. NEVER USE A FLAME TO CHECK FOR
LEAKS. Make this test in a well ventilated and spark-free area and where there are no open flames.
•
In cold weather the size of the flame will be smaller. To produce a larger flame, pre-warm the cylinder to room temperature prior to use.
REMOVE CYLINDER FROM TORCH WHEN NOT IN USE
1.
Make sure regulator valve is closed by turning flame adjustment knob (1) fully clockwise until it stops. Hand tighten only. Do not force.
2.
When torch is cool, disconnect cylinder and store torch and cylinder separately and out of reach of children. Observe cautions on
cylinder label.
3.
Do not expose cylinders to temperatures in excess of 120ºF.
4.
Store cylinders in well ventilated areas.
DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS | NE PAS JETER CES AVERTISSEMENTS ET CES INSTRUCTIONS
NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES | NÃO DESCARTE ESTES AVISOS DE ATENÇÃO E INSTRUÇÕES
LIGHTING AND OPERATION
200 Old Wilson Bridge Road
Columbus, OH 43085
STORAGE
419843
02/20