relative humidity, it may have different dehumidifying capacity.
3. In the same room temperature, the dehumidifying capacity is higher in higher relative humidity and the dehumidifying capacity is lower in
lower relative humidity. In the same relative humidity, the dehumidifying capacity is higher in higher temperature and the dehumidifying
capacity is lower in lower temperature.
4. If the dehumidifier is placed in the cabinet, its dehumidifying capacity may highly reduce in a short period after operating due to the
humidity in the cabinet has been highly reduced.
5. For 5°C / 10°C / 15°C /20°C /25°C / 30°C of room temperature and 80% of relative humidity the dehumidifying capacity is respectively
around 2 / 4 / 6 / 8 /10 liters of water when the air outlet is fully open.
Operation
1. Please place the machine unit upright to avoid misoperation and unusual sound.
2. Plug in the device.
3. Press the power switch (1) to turn on the device. The full water tank indication light (10) starts to illuminate continuously. The fan begins
to operate.
4. If the water tank (3) is full or the water tank (3) isn't installed in correct position then, the full water tank indication light (10) starts to
flashing.
5. When the full water tank indicator light (10) is flashing, the compressor installed inside the machine stops so that it does not condense
water until the water tank is empty or set in the correct position, but the fan continues to run.
6. To remove the water tank (3) please do hold the water tank sides and pull out. Look at picture 3.
7. To empty the water tank (3), tilt it as shown at picture 5 and drain the water slowly. Then reinstall the water tank (3) in the dehumidifier.
8. Press the power switch (1) again to turn off the device, the unit machine stops running.
Continuous drainage function
1. If you need to dehumidify the air for a long time, you can use the continuous drainage function.
2. Pull the rubber plug (11), then insert the attached continuous drain hose (7) as on picture 2.
3. After ending the continuous draining, replace the rubber plug (11) and switch off the device.
Continuous drain hose: length: 30 cm, internal diameter: 17 mm, external diameter: 19 mm.
Cleaning and Maintenance
1. Turn off the unit and disconnect the power plug before starting any cleaning or other routine maintenance.
2. To avoid the risk of electric shock, never sprinkle or spill water on the dehumidifier when cleaning.
3. Turn off the unit and empty the water out of the water tank when moving the device. Be sure to hold the handle while moving.
4. Wipe up the dehumidifier with wet cloth (put it into the water and wring it out).
5. Don't dismantle the floater (6) from the water tank (3).
6. Prior to continuous operation for a long duration, periodical checking is required especially for the net air filter (8), the drain hose (7), or
the like.
7. Clean net air filter (8) and filter's housing (9) every two weeks by vacuum cleaner. Look at picture 4. The dehumidify capacity may
reduce when the filter net is clogged with defilement.
8. Don't clean the device with gasoline, thinner or liquid detergent.
TECHNICAL DATA:
Dehumidify capacity at 30°C / 80% RH): 10 liters / 24 hours
Dehumidify capacity at 27°C / 60% RH): 5 liters / 24 hours
Noise level: <= 45dB
Water tank capacity: 2,2 liters
Air flow: 120 m3 / h
R290 coolant weight: max. 35 grams
Ratted Input Power: 200W
Max. Ratted Input Power: 245W
Power supply: 220-240V ~50Hz
Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odour.
The maximum refrigerant charge amount: 35g.
6