STEP-IV WIRING
FOR THROUGH WIRING USING CONDUIT
* Remove hole plugs (N) for the conduit entry.
* Use pipe sealant before engaging conduit
fittings to prevent water leakage.
* Loosen screw (G) and remove wire cover (H).
* Insert fixture lead wires (Q) thru grommet (R).
* Make the wire connections.
* Replace cover (H) making sure not to pinch wires.
STEP-V LAMPING
METAL HALIDE - PULSE START OR HIGH PRESSURE SODIUM
* Make sure that the lamp size is medium base and
type matches the ballast specifications.
* Replace reflector (F).
* Engage the lamp to socket (S).
* To ensure proper contact, loosen the lamp
one turn then retighten.
FLUORESCENT
(Fig. 9)
CAUTION: This is a twist lock socket.
Do not force lamp into socket.
* Make sure that the lamp size and
type matches the ballast specifications.
* Replace reflector (F).
* Engage the lamp to socket (S) and
rotate clockwise to lock in place.
REPLACING LED RING
Contact Hubbell Lighting technical services for replacement LED ring.
* CAUTION: Gently disconnect each LED ring (W)
and insert connector (Y) thru wireway hole (Z).
* Loosen (4) screws (K) then remove LED assembly.
* Remove three LED ring screws and nuts (P). Remove LED ring and
secure new replacement LED ring with screws and nuts.
* Insert connector (Y) thru wireway hole (Z).
Connect connector (Y) to new LED ring.
CAUTION : Ensure proper pin and guide slot orientation and secure firmly.
* Secure LED assembly to housing using (4) screws (K).
Hubbell Lighting, Inc.
A subsidiary of Hubbell Incorporated
701 Millennium Blvd • Greenville, SC 29607
Phone: (864) 678-1000
INSTALLATION INSTRUCTIONS
LAREDO LCC LUMINAIRE
(Fig. 2)
(Fig. 3)
(Fig. 7)
F
(Fig. 4)
(Fig. 4)
(Fig. 4)
B
GRN
BLK
WHT
FIG. 6
(Fig. 8)
FIG. 9
(Fig. 10)
LED RING
(Fig. 4)
H
J
Q
FIG. 7
F
S
FIG. 10
Doc. Number:
Revision: *
PAGE 2 OF 8
PAGE 2 DE 8
PAGINA 2 DE 8
R
S
FIG. 8
P
93015006

Publicidad

loading