TECHNICAL FEATURES:
20A resistive load - 8A motor load (26/10A 250V Fox G06)
(Max absorption with 20m of cable: 10A)
Wire gauge: 8,8mm (0,35in)
Operating temperature:
With H07 RNF cable: min.-15°C (-59°F) – max.+60°C (+140°F)
With VVF A07 cable: min.+5°C (+41°F) – max.+60°C (+140°F)
Max depth: 10m (32,8ft) Olympic – Fox – Fox G06 /
20m (65,6ft) Flotec / 40m (131,2ft) Supertec
Protection Grade: IP68
TERMINAL CONNECTIONS:
Please follow the Figure of the terminal connections table
The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protection
shall null and void the warrany in the event the float breaks.
Mod.01: single function - only emptying or only filling (Fig.1). The grounding wire is always yellow
and green.
Mod.02 – Mod.03 double function (the fitter can choose the emptying Fig.2 or filling Fig.3 when
installing):
Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and
closes when the float is up. Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit closes when float is down and
opens when the float is up. Note: the brown wire must be insulated.
HOW TO FIX:
COUNTERWEIGHT
NOTES: DO NOT TAMPER THE FLOAT SWITCH
Before any operation on the float remember to disconnect the power supply from the main power.
Check that the maximum motor power does not exceed the float's electrical values.
The electrical cable is part of the floating switch, thus in case of cable damage, the float itself has to
be replaced.
Counterweight or Fixing Kit are available on request as accessories.
No joints should be made on the float switch cable, as immersion of such joints could cause short circuits
or electrical shocks.
ENGLISH
EASY COUNTERWEIGHT
Activation angle:
45°
FIXING KIT