SPECIFICATIONS
• Voltage: 12VDC (LX-1360) /
• Motor Amps: 16A (LX-1360) / 3A
• Flow Rate: 11 GPM (40L/Min)
• Suction: LX-1360, 10 ft. (3m) / LX-1361, 32 ft. (10m)
• Self-Priming: Up to 10 ft. (3m) above liquid level
• Inlet Diameter: 3/4" (19mm), Pipe Thread
• Outlet Diameter: 1" (25mm), Pipe Thread
• Maximum Liquid Temperature: 140°F (60°C)
• Inlet & Outlet Connection Type: Barb
2 pcs. Connectors 3/4" (19mm)
2 pcs. Connectors 1" (25mm)
• LX-1360 Dimensions: 10" x 9.75" x 5.75" (270 x 245 x 142mm)
• LX-1361 Dimensions:
• LX-1360 Net/Gross Weight: 9 lbs. / 9.5 lbs. (4kg. / 4.2kg.)
• LX-1361 Net/Gross Weight:
Preliminary Inspection: Verify that all components are present. Request any missing parts from Lumax.
• Check that the Pump has not suffered any Damage during Transport or Storage.
• Carefully clean the Suction and Delivery Inlets and Outlets, removing any dust or other packaging material
that may be present.
• Check that the Electrical Data corresponds to those indicated on the Data Label.
• Always install in a well illuminated area.
• Install the Pump at a minimum height above the surface of 0.3" (0.80cm).
Positioning and Configuration: In the case of installation in the open air, proceed to protect the Pump by
providing a protection roof.
Note: The Pump can be installed in any position (Pump axis, vertical or horizontal). The Pump must be
secured in a stable way using the holes on the bed of the motor and vibration damping devices.
Note: The broad range of Pump accessories make it suitable for many different uses, installations and
applications. The supporting base can be positioned in different ways.
Electrical Power Supply: The Pump should be powered by a Safe Source and Direct Current line: Battery
or 12V Power Supply with Safety Transformer. The maximum acceptable variations from the electrical
parameters are: +/- 10% Voltage
Warning: Power supply from lines with values that do not fall within the indicate limits could cause serious
damage to the electrical components and reduction of working performance.
Electrical Connections: It is the responsibility of the installer to carry out the electrical connections in
compliance with the applicable regulations. Comply with the following (not exhaustive) instructions to ensure
a proper Electrical Connection:
• Before installation and maintenance make sure that power supply to the electric lines has been turned OFF.
• Use cables with minimum cross-sections, rated voltages and installation type that are suitable for the
characteristics of the Pump Specifications.
• Always close the cover of the terminal strip box before switching on the power supply, after having checked
the integrity of the seal gaskets that ensure the IP55 protection grade.
4
110V-120VAC (LX-1361)
(LX-1361)
11.5" x 9.75" x 7" (290 x 245 x 180mm)
13 lbs. / 14 lbs. (6 kg. / 6.5kg.)
• Power: 300W (LX-1360) /
• On/Off Switch
• Duty Cycle: 30 Minute Continuous
• Speed: 2850 RPM
• Pressure: 40 PSI (3bar)
• Viscosity: Up to 1000 cps./4600 SSU max.
• PH (High): 8PH
• Cord Length: 6.4 Ft. (2m)
• Mounting Base (LX-1360): 3" x 2" (76 x 50mm)
• Mounting Base (LX-1361):
330W (LX-1361)
4" x 3" (100 x 80mm)