Jacob Delafon DTV Modo De Empleo página 89

Dispositivo digital
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting table
Symptoms
10. Water leaking from the
valve.
CAUTION: Risk of personal
injury or product damage. Turn
off the main power and water
supply.
11. Hot water only, the valve
shuts down.
Probable Cause
A. Connections are not secure.
B. Seals are worn or damaged.
C. Internal leak.
A. Hot and cold lines are reversed.
English
Recommended Action
A. Check all connections. Make
adjustments as needed.
B. Order a seal service pack and
replace all seals.
C. Unit requires overhaul. Contact
your Jacob Delafon authorized service
representative.
A. Switch hot and cold water supply
connections. Verify the hot water
supply is connected to the inlet
marked "H" and the cold water
supply is connected to the inlet
marked "C."