BEFORE USE
Make sure to install the air purifier on a stable surface, the sides and top cover should be
at least 30cm away from the wall and furniture.
Checking, installing or replacing the filters
•
Unplug the air purifier and turn the appliance upside down
•
Press down the bottom cover while turning to the left to open it
•
Check if the filter is well positioned, install it if it is missing or replace it if necessary
Caution : remove the protective plastic film of the filter before installing it
Filter replacement
•
The filter has a using period of 1440 hours, after that period, replacement is necessary
•
The Fan speed indicator lights will flash to indicate that the filter needs to be
replaced
•
Once the filter is replaced, press and hold the Fan speed touch key to reset the using
period counter
USE
Start
•
Press the Power Switch on the top cover to start the air purifier
•
The appliance emits a sound and all the indicator lights flash then switch off
•
The standby mode activates automatically
Standby mode
•
Press the Power Switch on the top cover to exit the standby mode
•
The fan starts automatically on low speed and the ambiance light switches on (the
Fan speed touch key and the Low speed indicator light are on)
Fan speed setting
Press the Fan speed touch key to select the desired speed or to activate the sleep mode
(the corresponding indicator light switches on).
Sleep mode
•
In sleep mode the fan runs only at low speed and the ambiance light switches off
•
Press any touch key to exit the sleep mode
•
The timer is not available in sleep mode
Timer
Press the Timer touch to select the desired operation time between 1, 2, 4 or 8 hours (the
corresponding indicator light switches on).
Child Lock
•
Press and hold the Timer touch key for 5 seconds to activates the child lock mode
(the indicator light switches on and all the touch keys are disabled).
•
Press and hold the timer key for 3 seconds to exit the child lock mode (the indicator
light switches off and all touch keys resume to regular use).
7