6 Tech ica specificati
6 Technical specifications
E
de
.
Operating voltage
Setting range, temperature (P1)
Setting range, minimum speed (P2)
Fan speed
Temperature sensor
Max. fan output
Switched current
Controller
Alarm
Output, mode of operation
Software category
Level of contamination
Rated surge voltage
Temperature of ball pressure test
Voltage and amperage of EMC testing 230 V 0.1 A
Protection category
Operating temperature
Storage temperature
Connection
Mounting
Enclosure
Dimensions
Tab. 1:
Technical specifications
7 Supply includes
Qty.
Desig ati
1
Speed control
1
Remote sensor
1
Set of assembly instructions
Tab. 2:
Supply includes
10
3120.200
100 - 230 V AC, (-15, +10 %), 50/60 Hz
20...55°C, 68...131°F
~0 - 100 %
min. speed ...100 %
Length 1.80 m
300 W
max. 2 A
Phase cross-over
Relay, change-over contact 5 A, cos ϕ = 1
(not suitable for SELV)
Type 1Y
A
2
4 kV
75°C
IP 20
0°C...+55°C
-30°C...+70°C
Screw terminals single or multi-wire 0.75...1,5 mm
On support rail 35 mm EN 50 022
Polycarbonate, UL 94 V-0
W x H x D: 105 x 90.5 x 60.2 mm
8 Guarantee
This unit is covered by a 1-year guarantee
from the date of supply, subject to correct
use.
In the case of incorrect use or connection,
the guarantee of the manufacturer ex-
pires. No liability is accepted for damage
arising in such cases.
Rittal Speed control assembly and operating instructions
s