Avoid pointing the detector towards objects that may move in the wind, such as curtains,
tall plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
⚫
Must be installed by professional electrician.
⚫
Disconnect power source.
⚫
Cover or shied any adjacent live components.
⚫
Ensure device cannot be switched on.
⚫
Check power supply is disconnected.
➢
Unload the front cover directly by screw-driver. (figure1).Find the wire hole with gasket in
the bottom and pass the power wire through hole.
➢
Fix the bottom on the selected position with the inflated screw (refer to figure 2).
➢
Connect the power wire into connection-wire column according to the connection-wire
diagram.
➢
Install back the front cover, tighten the screw and switch on the power. Then you can test
it.
➢
Figure1
CONNECTION-WIRE DIAGRAM:
(See the right figure)
SENSOR INFORMATION:
Height of installation: 1.8-2.5m
TEST :
➢
Turn the SENS knob clockwise on the maximum (+).Turn
the TIME knob anti-clockwise on the minimum (-).Turn the
LUX knob clockwise on the maximum (sun).
➢
Switch on the power; the sensor and its connected lamp will
have no signal at the beginning. After Warm-up 30sec, the
sensor can start work .If the sensor receives the induction
signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working within 10sec±3sec and the lamp
would turn off.
➢
Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than
3LUX, the sensor would not work and the lamp stop working too. If the ambient light is
Figure2
less than 3LUX (darkness), the sensor would work. Under no induction signal condition,
the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
the sensor lamp could not work! If the lamp is more than 60W, the distance between
lamp and sensor should be 60cm at least.
Detection Distance: Max.12m
(SUN) position, otherwise