The MudRunner™ is essentially a power assisted corner applicator and is intended to
work with all of the same tools that the corner applicator does now, primarily with corner
finishers, but also with mudheads and other tools.
Operation
In general, you will want to use joint compound thicker than you would normally use for
finishing corners. To start, it is recommended to thin the compound to about midway
between angle compound and boxing compound.
The MudRunner is filled with compound very much like an existing corner applicator.
Insert the filler valve fully into the discharge tube of the pump. You will need to
maintain pressure against the pump as the MudRunner is filled or the pumping
pressure will force the MudRunner off of the filler valve.
Whenever there is any compound in the tool, it is under constant pressure from the
internal gas spring. Pump until the MudRunner piston is forced all the way back to its
stop. Once full, do not continue pumping. Attach the finishing tool to the ball outlet of
the MudRunner as you would with a corner applicator. Compound flow is controlled by
twisting the control tube. The more you twist, the faster compound flows.
Place the tool at one end of the joint to be finished with the filler valve pointing away from the angle. Twist the control
tube. If using the tool for the first time, you may want to wait an instant till you see compound filling the tool. Move the
tool toward the other end of the joint, relaxing your grip on the control tube when you wish compound flow to stop. The
outlet valve will automatically close off compound flow as you relax your grip. Place the tool at the other end of the joint
and repeat, relaxing your grip on the control tube when you have overlapped the point where the previous pass ended.
Maintenance
It is good practice to empty the tool if it is not going to be used for a time. The outlet end of the tool can be placed in a
bucket of water as is common with other tools. DON'T SUBMERGE THE HANDLE END OF THE TOOL! The handle
end can be sprayed with water, but should not be submerged. Do not directly spray the white cover at the top end of the
control tube. Should water find its way into the handle, stand the handle up vertically to allow it to drain.
Clean the tool by removing the main tube cap. Clean all compound from the inside of the cap, the filler valve and around
the piston. If compound has gotten on the backside of the piston, then remove the main tube and clean as needed.
Lubricate the rubber piston seal with Bazooka
Keep the area around the white cover clean. Avoid flushing joint compound or debris under the white cover as it may
make operation of the control tube more difficult. Lubricate the control mechanism through the pinhole above the screw
after every cleaning and as needed to maintain proper operation of the tool. Replace the main tube and the main tube
cap as soon as the tool is clean to reduce the chances of damaging the tool
SYMPTOMS
1. Compound flows too quickly, finish is sloppy,
compound overflows the finishing tool.
2. Compound doesn't flow fast enough, have to
move finishing tool very slowly to get good
finish.
3. MudRunner requires high effort to fill.
4. Compound leaks from filler valve when
removed from pump.
5. Compound leaks past piston.
The MudRunner™
oil.
®
TROUBLESHOOTING
SOLUTIONS
1. Compound too thin. Thicken compound till excellent results
obtained.
2. Compound too thick, or control tube only partially twisted.
Ensure control tube is fully twisted to obtain full flow, or thin
compound.
3. Compound too thick, or filler valve is damaged.
4. "Trash" holding filler valve open, or valve damaged. Use a
screwdriver to fully open valve to flush "trash" out.
5. Seal or tube damage. Repair/Replace unit (see warranty).
The MudRunner
© 2006 Ames Taping Tool Systems Inc.

Publicidad

loading

Resumen de contenidos para AMES MudRunner

  • Página 1 Whenever there is any compound in the tool, it is under constant pressure from the internal gas spring. Pump until the MudRunner piston is forced all the way back to its stop. Once full, do not continue pumping. Attach the finishing tool to the ball outlet of the MudRunner as you would with a corner applicator.
  • Página 2 Bombee hasta que el émbolo del MudRunner se fuerce completamente hasta su parada. Una vez repleto, no sigua el bombeo. Conecte la herramienta de terminado a la salida de la pelota del MudRunner como lo hace en el Aplicador de Ángulos. El fluido del compuesto es controlado torciendo el tubo del control.