GENERAL
PN Series Standard Duty plugs and receptacles are
designed to offer superior safety, durability and consistent,
electrical contact performance. Please follow the
instructions below to ensure the proper installation,
operation and maintenance of this product.
WARNING
There are inherent dangers
associated with electrical
DANGER
products. Failure to follow safety precautions can result
in serious injury or death. These instructions must be
CAUTION
followed to ensure the safe and proper installation,
operation and maintenance of the MELTRIC devices.
Before installation, disconnect all sources of power to
NOTICE
the circuit to eliminate the risk of electrical shock.
ADVERTENCIA
RATINGS
DANGER
MELTRIC's PN7c and PN20 plugs & receptacles are
listed in accordance with UL 1682, CSA 22.2 No. 182.1
CAUTION
and IEC 60309-1. The amperage, voltage and environmental
ratings are indicated in Table 1.
AVISO
Table 1 - General Ratings
PN7c
PN20
Current
15 A
20 A*
Interrupting
Non-Current
-
Interrupting
480VAC/
Voltage
600VAC
130VDC
Frequency
50-400 Hz
50-400 Hz
IP66/IP67
Environmental
IP66/IP67
IP54/IP55
*15 A above 480VAC
INSTALLATION
PN Series plugs and receptacles should be installed
by a qualified person in accordance with all applicable
local and national electrical codes.
Before starting, verify that the power has been
disconnected, all product ratings are appropriate
for the application and the conductors meet code
requirements and are within the capacities of the terminals
WARNING
noted in Table 2.
Table 2 — Wiring Terminal Capacity* (in AWG)
DANGER
Wire Size Min
Model
14
PN20
CAUTION
14
PNHT
18
PN7c
NOTICE
*Capacity is based on THHN wire sizes.
ADVERTENCIA
General Notes & Precautions
1. This product must be installed by certified personnel.
2. NOTICE: Do not tin terminal wire ends.
3. NOTICE: Do not use moisture repellent sprays on
the contacts.
4. Do not back terminal screws fully out.
5. Self-tapping screws are provided for use with
some polymeric accessories. High torque may be
required to drive them in. NOTICE: Once they are
seated, care should be taken in order to avoid
over-tightening them against the plastic material.
6. NOTICE: MELTRIC threaded handles come with
tapered style threads. The use of fitting seal tape
is required to maintain watertightness of all NPT
fittings and joints.
7. Various handles and cord grip options may be
used. These instructions are based on handles
provided with integral multi-layer bushing cord
grips.
8. If the plug and receptacle are stainless steel then
stainless steel accessories must be used.
INSPN P
ENVIRONMENTAL
Optimum operating conditions are achieved by
installing IP66 /IP67 plugs and receptacles with the
latch at the top.
NOTICE: To prevent water ingress, non-watertight
plugs/receptacles must always face downwards when
not mated.
Wire Strip Length
Wire strip lengths are indicated in Table 3. Strip lengths
for cable sheathing will depend on the specific application.
When used with handles, the cable sheathing should
extend into the handle to ensure secure cord gripping.
Table 3 - Wire Strip Lengths – Dimension A
Device/Contact Inches
PN20
PNHT
PN7c
Terminal Screw Tightening Torques
The wiring terminals are spring-assisted to prevent
loosening due to wire strand settlement, vibration
and thermal cycling. NOTICE: Avoid over-tightening.
Appropriate tools and tightening torques are indicated
in Table 4.
PNHT
Table 4 - Terminal Screw Tightening Torques
-
Device/Contact
PN20
30 A
30 A
PNHT
480VAC/
PN7c
130VDC
Wiring the Terminal Connections
50-400 Hz
Verify that power has been disconnected prior to
IP44
wiring the conductors to the plug and receptacle.
Wiring must be made according to all applicable local
and national electrical codes. Check that the rating is
WARNING
correct for the installation.
Follow the conductor-coding and terminal markings
DANGER
detailed in Table 5. WARNING: This product must be
electrically grounded. A grounding terminal is provided
CAUTION
on all metal accessories, with a green screw and a
washer.
NOTICE
For Screw Type Terminals
Insert cable through handle and strip cable jacket to
ADVERTENCIA
adequate length. The cable jacket should extend at
least 1/2" into handle. Back out terminal screws only
DANGER
far enough for conductor to clear. Strip each conductor
Wire Size Max
per Table 3. Twist the strands of each conductor together
CAUTION
8
and insert fully into the terminal. Tighten terminal screws
8
to torques indicated in Table 4.
AVISO
10
Receptacle
Plug/Inlet
mm
Inches
mm
3/ 8
10
3/ 8
10
3/ 8
10
3/ 8
10
5 /16
8
5 /16
8
Torque
Required Screwdriver or
Allen Wrench
in-lbs
N-m
8
0.9
3 mm or 1/8" precision tip
8
0.9
3 mm or 1/8" precision tip
8
0.9
3 mm or 1/8" precision tip
Table 5 - Conductor Coding and Terminal Markings
Terminal ID
Function
Green equipment grounding conductor
"G", "E" or GND
only (or green with yellow stripe).
White or gray, system ground
"N"
(neutral conductor only "N")
PN20/PNHT Models
"1" or "R1" (Black)
"Hot" conductors, no specific lettered terminal
"2" or "S2" (Red)
applies to any specific colored conductor
"3" or "T3" (Blue)
PN7c Model
"Hot" conductors, no specific lettered terminal
"1" to "6"
applies to any specific colored conductor
ASSEMBLY
Verify power has been disconnected prior
to assembly.
For In-Line Connections
WARNING
Insert the cable through the handle and gasket. Strip
the cable jacket to provide a workable wire length, being
DANGER
mindful that the jacket must extend into the handle
to achieve a secure grip. Then strip the wires to the
CAUTION
lengths indicated in Table 3. When applicable back out
the terminal screws far enough (but not completely) to
allow the conductors to pass. Insert the conductors fully
NOTICE
into their respective terminals and hand tighten to the
torques indicated in Table 4.
ADVERTENCIA
Receptacle (or Inlet)
Bushing
DANGER
CAUTION
AVISO
Strain
Relief
Compression
Color-Coded
Handle
Nut
Gasket
For Mounted Receptacles /Inlets
Insert the cable through the wall box and cut to allow
adequate length. Strip the cable jacket to allow a workable
wire length. Strip the individual cables to the lengths
indicated on Table 3. When applicable back out the
terminal screws far enough (but not completely) to allow
the conductors to pass. Insert the conductors fully into
their respective terminals and hand tighten to the torques
indicated in Table 4. Assemble the receptacle/inlet and the
color gasket to the box with the appropriate hardware.
Hole Pattern for Custom Mounting
In applications where custom mounting to a panel
or box is desired, the clearance and mounting holes
should be drilled as indicated in the following diagram
and Table 6.
B
C
Table 6 - Custom Mounting Dimensions
'A'
'B'
Model
Inches
mm
Inches
PN20
2
50
1.65
PNHT
2
50
1.65
PN7c
2
50
1.65
NOTICE: In order to maintain the IP protection provided
by PN models in custom installations, watertight seals
should be used under the heads of the four mounting
B
'C'
mm
Inches
mm
42
0.19
5
42
0.19
5
42
0.19
5

Publicidad

loading

Resumen de contenidos para Marechal Electric PN Serie

  • Página 1 NOTICE NOTICE: To prevent water ingress, non-watertight into their respective terminals and hand tighten to the plugs/receptacles must always face downwards when meltric.com A COMPANY OF MARECHAL ELECTRIC torques indicated in Table 4. not mated. ADVERTENCIA Receptacle (or Inlet) Bushing...
  • Página 2 bolts and they must be retained by a lock washer and remove the silver-nickel, butt-contact tip and degrade nut on the inside of the box or panel. Alternatively, four the contact consistency. Sprays should not be used blind holes may be drilled and threaded to accommodate since they tend to collect dirt.
  • Página 3 étanches doivent toujours A COMPANY OF MARECHAL ELECTRIC Insérez complètement chaque conducteur dans la borne être orientées vers le bas lorsqu’elles ne sont pas appropriée et resserrez manuellement les bornes en ADVERTENCIA RENSEIGNEMENTS GÉNÉRAUX...
  • Página 4 boulons de montage puis les immobiliser à l’aide d’une Utilisez un linge propre pour enlever les dépôts de rondelle de blocage et d’un écrou vissés à l’intérieur du poussière ou de corps étrangers. boîtier ou derrière le panneau. Vous pouvez également MISE EN GARDE : Les surfaces de contact ne doivent percer et fileter quatre trous borgnes pour y insérer les en aucun cas être limées, car cela éliminerait l’embout...
  • Página 5 AVISO: Para evitar el ingreso de agua, los tomacorrientes cubierta del cable deberá penetrar en la manija para un A COMPANY OF MARECHAL ELECTRIC WARNING CAUTION y clavijas que no son a prueba de agua, deberán mantenerse agarre seguro.
  • Página 6: Operación

    Dimensiones de Barrenos para Montaje Especial PROVISIONES PARA BLOQUEO WARNING Los tapas de los receptáculos pueden ser bloqueados En aplicaciones en donde se requiere montaje especial con un tornillo o un pin excepto los PNHT. a un panel o caja, los barrenos y la distancia entre DANGER ellos, deberán de hacerse de acuerdo con el diagrama Tornillo: Con la clavija insertada ó...

Este manual también es adecuado para:

Pn20PnhtPn7c