WARNING
!
Using SmartStream
ment equipment
SmartStream
UV units can be installed as a
final disinfection method within a water treat-
ment system train or as pretreatment to protect
sensitive components, such as reverse osmosis
membranes, from bio-films.
The injection of chemicals into the water should
be done on the outlet of the SmartStream
system to ensure UV light degradation of the
chemical or the introduction of turbidity within
the UV feedstream does not occur.
A 5 micron particle filter should always be
installed immediately before the SmartStream
system.
Be certain that the feed water meets all criteria
within the Feed Water Specifications section of
this manual.
WARNING
!
Installation Guidelines
• DO NOT allow this system to remain ON with-
out water in it for extended periods of time.
• DO NOT install the system near any source
of heat. Also, DO NOT install the system near
any device or break out area that would be
adversely effected by water.
• DO NOT install this system higher in elevation
than 10,000 feet above sea level.
• DO NOT install the system backwards with
the feed water line connected to the outlet.
• DO NOT install where system is exposed to
harsh chemicals or may be subjected to being
struck by moving equipment, carts, mops or
any other item that may cause damage.
• DO NOT install the system outdoors. Keep
system away from moisture, rain, and direct
sunlight. Ambient air temperature must remain
below 122°F and relative humidity must
remain below 95%.
• DO NOT allow the system to freeze.
• The system MUST be mounted on a surface
and with mounting hardware that is sturdy
enough to support the weight of the wetted
system.
• The system MUST be plugged into an uninterrupt-
ed power supply that matches the rated power
requirement of the system. In European installa-
tions, the appliance is to be supplied through a
residual current device (RCD) having a rated resid-
ual operating current not exceeding 30 milliamps.
with other water treat-
• The system MUST be installed in accordance
with all applicable national, state and local
codes.
• A prefilter with a 5 micron minimum particle
size reduction must be installed on the inlet
line to the system. Additional pretreatment
may be necessary so that the feedwater con-
forms to the Feed Water Specifications sec-
tion on page 8.
• Plumbing materials sensitive to UV light, typi-
cally plastic materials, should not be connect-
ed directly to the system. To prevent UV deg-
radation at the plumbing connection points on
the system, use one foot minimum of copper
or stainless steel plumbing material to connect
to the inlet and to the outlet of the system.
• IF water hammer is evident, install water ham-
mer arrestors before the system.
• Always back-up valves and fittings with a
wrench when constructing plumbing to reduce
unnecessary stress on the system and its
plumbing.
Position the system in a suitable location. Make
sure there is enough clearance between the end
of UV chamber and any obstructions, to allow for
the removal of the lamp and quartz sleeve.
SmartStream
installed as close as possible to the treated water's
point of use.
3
UV disinfection systems should be