1. Carefully remove the stylus from the cartridge
¬
(see
).
2. Connect the wires from the headshell to the pins
­
on the cartridge (see
). Use the following table for
the correct connections. Note: To prevent "ground
loops" and hum, do not make common (ground)
connections at these terminals.
R
RED
RG
GREEN
L
WHITE
LG
BLUE
3. Mount cartridge in the headshell and replace sty-
®
¬
lus (see
and
). Do not force. Note: Screws
can be threaded up from the bottom to provide max-
imum record clearance.
4. When the Dynamic Stabilizer brush is set to the
Ã
operating position (see
A), it absorbs 0.5 grams
of tonearm tracking force. The proper tonearm set-
DYNAMIC STABILIZER/DE-STATICIZER
The M97xE's exclusive viscous-damped Dynamic
¯
Stabilizer (
) maintains a uniform distance be-
tween the cartridge and the record under difficult
playing conditions, such as those caused by
warped records or mismatched tonearm mass.
When such stabilization is not required, the stabiliz-
er can be locked into its up position, which can im-
prove sound quality under ideal playing conditions.
Over 10,000 conductive fibers in the stabilizer
brush neutralize static charges on the record sur-
face and conduct them to the ground. Additionally,
the fibers sweep the record groove clean of dust
and dirt in front of the stylus tip. The Stabilizer also
absorbs impact to prevent record or stylus damage
if the arm is accidentally dropped on a record.
For monophonic playback of recordings, the left and right channels should be connected in parallel. This
is accomplished most conveniently by setting the function switch on the associated preamplifier to "A + B"
or "MONO." If the existing equipment has a single monophonic input, the two channels of the cartridge
should be paralleled and connected to this single input.
CARTRIDGE OPERATION
1. Make certain cartridge is correctly mounted in
tonearm and stylus is properly inserted in cartridge.
2. Protect stylus with stylus guard when dusting
turntable.
3. Regulate tonearm set-down to prevent stylus
from striking edge of turntable or record.
4. Do not handle tonearm while record is being
played. Use cueing device if available.
5. If manual set-down is necessary, release arm as
soon as stylus engages groove.
6. Do not activate arm without record(s) on turntable.
7. Do not use damaged records.
8. Check tracking force and anti-skate adjustments
periodically. The Shure SFG-2 Tracking Force
Gauge, available through your Shure dealer, pro-
vides a simple way to accurately set tracking force.
E2000, Shure Incorporated.
27A3013
(TH)
Model M97xE User Guide
CARTRIDGE INSTALLATION
tings for the recommended range of stylus tip track-
ing forces are:
RECOMMENDED
RECOMMENDED
RANGE
(effective at
stylus tip)
(RIGHT "HOT")
(RIGHT GROUND)
(LEFT "HOT")
Maximum 1.5 g
(LEFT GROUND)
OPTIMUM 1.25 g
Minimum 0,75 g
5. Make the following final adjustments. Consult
your turntable instructions.
Cartridge Overhang: If adjustable.
Anti-Skate: If this adjustment is not specified in
your turntable instructions, use the same setting
as for tracking force.
Tonearm Height: If adjustable.
SIDE GUARD STYLUS PROTECTION
The Side-Guard stylus protection system helps
prevent stylus damage if the cartridge accidentally
slides across a record. This system responds to
side thrusts on the stylus by withdrawing the entire
stylus cantilever and tip safely into the stylus hous-
ing before the cantilever can be damaged.
MONOPHONIC PLAYBACK
Use the supplied brush to clean the stylus and dy-
namic stabilizer. Brush only from back to front, as
shown (
brush. Use alcohol or an alcohol-distilled water
solution to clean the stylus. Commercial cleaning
solutions may damage the stylus.
TRACKING FORCE (in grams)
TONEARM SETTING
TONEARM SETTING
Dynamic
Dynamic
Stablilizer
Stabilizer
Down (operating)
Up (non-operating)
Ã
A
2.0 g
1.75 g
1.25 g
B
A
guard
SYSTEM
STYLUS CLEANING
°
). Do not use liquids on the stabilizer
Printed in U.S.A.
Ã
B
1.5 g
1.25 g
0.75 g

Publicidad

loading

Resumen de contenidos para Shure M97xE

  • Página 1 Commercial cleaning 8. Check tracking force and anti-skate adjustments solutions may damage the stylus. periodically. The Shure SFG-2 Tracking Force Gauge, available through your Shure dealer, pro- vides a simple way to accurately set tracking force. E2000, Shure Incorporated. 27A3013 (TH) Printed in U.S.A.
  • Página 2 Cette garantie ne couvre pas l’usure de la pointe de lecture. Si ce produit Shure présente un des défauts décrits plus haut, le remballer soigneusement, l’assurer et le retourner en port payé à...
  • Página 3 Conserve el comprobante de compra. Shure no se hace res- Shure para su reparación. La unidad será reparada o reemplazada y ponsable por daños consecuentes.
  • Página 4 SHURE Incorporated Web Address: http://www.shure.com 222 Hartrey Avenue, Evanston, IL 60202–3696, U.S.A. Phone: 847-866–2200 Fax: 847-866-2279 In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414 In Asia, Phone: 852-2893-4290 Fax: 852-2893-4055 Elsewhere, Phone: 847-866–2200 Fax: 847-866-2585...