Operation

Operation
Thank you for deciding on the Testboy
This test adapter is an accessory for additional Testboy measuring instruments and testers, for example, to carry out safety or func-
tion tests using an installation tester. It has a type 2 connector for testing charge accessories for electric vehicles (EVSE Mode 3).
The solid housing of the Testboy
The Testboy TV 900's LED display is intended as a guide value rather than a reading.
For this, suitable measuring/test equipment should be used!

Safety information

You have chosen an instrument providing a high degree of safety. To ensure safe and correct application, it is necessary to fully
read this operating manual before using the instrument for the first time.
1) Type 2 connector
2) Phase indicator
3) Banana jacks for phases L1, L2, L3
4) Banana jack for CP
5) Banana jack for PE
6) CP-State rotary switch
7) Phase rotary switch
8) CP-State E (Fault Simulation) button
9) Socket
10) BNC jack
11) Banana jack for N
12) PP-State rotary switch
13) PE Fault Simulation button
The following safety precautions apply:
If the display fails to indicate one or more functions, then
|
do not continue to use the instrument. It must be checked by
a specialist.
|
Avoid contact with the banana jacks (3, 4, 5, 11)! (Refer to
the figure)
The instrument must not be operated in a humid environ-
|
ment!
|
Always keep the instrument dry and clean. The housing
should only be cleaned using a damp cloth.
The various signals displayed by the voltage tester should
|
not be used for measurement purposes.

Function

The instrument simulates a connected electric vehicle and enables various charge states to be simulated. The TV 900 has various
measuring and tapping points. To switch on the instrument, connect the type 2 connector to a charge column. When the charge
column is enabled, the LEDs indicate the phase(s). The "CP-State" (Control Pilot Resistance) rotary switch can be used to simulate
various charge states. The banana jacks enable testing using various test leads. The BNC jack enables an oscilloscope to be used.
Additional measuring instruments can be connected to the socket. The phases can be switched with the relevant rotary switch. The
"PP-State" (Proximity Pilot Resistance) switch can be used to simulate a cable (N.C., 13 A, 20 A, 32 A, 63 A are selectable).
The "CP-State E" and "PE Fault Simulation" buttons can be used to simulate fault states. E.g. a PE conductor break.
WARNING
The socket has a maximum load capacity of 5 A! It is also important not to switch between phases under load!
12
®
TV 900, an EVSE (Electric Vehicle Supply Equipment) adapter.
TV 900 means that it can also be used under harsh operating conditions.
®
®
Testboy