Tighten all three studs and return the discriminator back to its normal position.
Alignment Checks
Once the changegiver has been securely fitted to the vending machine, check
reject lever operation and coin chute alignment. Do this without any power applied
to the machine.
Lever
Reject
Button
4mm
Lid
Check machine coin chute alignment by inserting
two of each coin denomination through the coin
entry slot of the machine.
Ensure that the inserted coins fall freely into the
changegiver and exit out into the machines cash
return cup.
Cable Connection
The changegiver may be fitted with more than one
cable, these may be intended for TX-RX
communications, drive an external display or to
extract audit data.
Once all relevant cables are connected and before
closing the machine door, tuck any unused cables
away tidily ensuring that none are trapped between
the reject lever mechanism and the vending
machine door. You can now switch ON the power to
the vending machine.
Check there is a minimum 4mm gap between
the machines reject lever mechanism and the
changegiver reject button.
Press the machine lever a couple of times and
ensure the lid of the discriminator opens and
closes correctly.
Page 3 of 10