TECHNICAL DATA
Input (supply) terminals: A1, A2
Nominal power consumption: 0,2 W
Number of operation modes: 1
Maximum number of transmitters: 32
Optic signalling of device operation: LED red diode
Additional antenna terminals: ANT
Relay output terminals: 11, 14
Number of terminal clamps: 5
Section of connecting cables: to 2,5 mm
Ambient temperature range: -10 ÷ +55
Casing protection degree: IP20
Overvoltage category: II
CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles.
If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range ac-
cording to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %,
metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium and high electrical power
lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative
influence on the range.
Input rated voltage: 12 ÷ 24 V AC/DC
Number of channels: 1
Transmission: radio 868 MHz
Coding way: unidirectional
Coding: addressing transmission
Range: up to 250 m in the open area
Relay parameters:
Operating position: free
Casing mounting: installation cable box Ø60 mm
Protection level: III
Pollution degree: 2
Surge voltage: 1 kV
Dimensions: 47,5 x 47,5 x 20 mm
Weight: 0,032 kg
1NO 2 A / 250 V AC AC3 500 VA
(dry contact)
2
C
o