Backward Current Protection – Fault/Error Code:
• Once the engine has been started, the unit will
turn off after five seconds of sensing large current
charging, typically due to the initial alternator surge,
which can be greater than 50 amps.
• After the engine starts, disconnect the black clamp (–)
and then the red clamp (+).
Over-Charge Protection – Fault/Error Code:
• Once the battery is fully charged, the charging
circuit automatically senses full charge and turns off
charging.
• Remove charge cord, and press and hold power
button to turn off unit.
Inspect all attachments for:
• Cuts or abrasions in the cable.
• Cracks or broken connectors.
• Excessive corrosion on any connections.
OPERATING ISSUE
The unit won't jump
start car.
The unit won't power
USB device.
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
PAGE 6 OF 18
LCD DISPLAY CONTINUED
0000
Overloaded USB Output Port – Fault/Error Code:
0000
TROUBLESHOOTING
CAUSES
Clamps are not making a good
connection to the battery.
The unit is not charged.
The vehicle's battery voltage is
over 15V.
The vehicle does not have a
battery.
The temperature of the jump
starter's internal battery is low.
The device is not turned on.
The jump starter is turned off.
1-800-295-5510
uline.com
• If the unit senses a current overload from either of
these ports, the unit will flash fault/error code
and turn off completely.
• Remove USB device and discontinue use of device
with this unit.
• Damaged housing.
• Broken LCD.
WARNING! If any of these problems are found,
discontinue using the jump starter and contact
Uline Customer Service at 1-800-295-5510.
RECOMMENDATIONS
Check for poor connection to
battery. Make sure connection
points are clean.
Check the battery charge status
and recharge unit if necessary.
You cannot use this jump starter
for this vehicle.
Follow the instructions on how to
use the Override Mode function.
Place the unit indoors at
temperatures above 32°F until
warm.
Turn on the device.
Turn unit on, if internal battery of
the jump starter is low, recharge.
0000