Descargar Imprimir esta página
GE Z-Wave ZW3005 Manual De Instrucciones
GE Z-Wave ZW3005 Manual De Instrucciones

GE Z-Wave ZW3005 Manual De Instrucciones

Publicidad

Enlaces rápidos

FCC / IC
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifications
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to the
antenna or the device is permitted. Any change to the antenna or the device could result in the
device exceeding the RF exposure requirements and void user's authority to operate the device.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils exempts de
licence d'Industrie Canada. Son utilisation est sujette aux deux conditions suivantes : 1) cet appareil ne
doit pas occasionner de brouillage préjudiciable et 2) cet appareil doit accepter toutes les interférences
reçues, notamment les interférences qui peuvent provoquer un fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de
ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont
été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en
milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et,
s'il n'est pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage
préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que des
interférences ne se produiront pas au sein d'une installation donnée. Si cet appareil occasionne
un brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer et
d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à essayer
de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est autorisée. Toute
modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le dispositif dépasse
les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur à utiliser ce dispositif.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC y con las
especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá aplicables
a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos condiciones:
(1) este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo debe aceptar
toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de Clase B,
de conformidad con el apartado 15 de las normas de la FCC. Estos límites están diseñados para
proveer protección razonable contra interferencias perjudiciales en una instalación residencial. Este
equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa según las
instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No obstante, no
hay garantías de que no ocurrirá interferencia en una instalación en particular. Si este equipo provoca
interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse encendiendo y
apagando el equipo, se recomienda que el usuario intente corregir la
interferencia por medio de la implementación de una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente
del circuito al que está conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW3005A | IC: 6924A-ZW3005A
Jasco Products Company | Model: ZW3005 / 14294
CAN ICES-3(B) / NMB-3(B)
All brand names shown are trademarks
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
of their respective owners.
GE IS A TRADEMARK OF GENERAL ELECTRIC COMPANY AND
Tous les noms de marque illustrés sont des marques
IS UNDER LICENSE BY JASCO PRODUCTS COMPANY LLC,
de commerce de leurs propriétaires respectifs.
10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114.
Todas las marcas que aparecen aquí son marcas
©JASCO 2017 | 14294 | ZW3005 | rev. 06/19/17 RT v3
registradas de sus respectivos dueños.
1.
Tools you will need
IMPORTANT!
The fixture controlled by the Z-Wave In-Wall Smart Dimmer must not
exceed 600 watts (Incandescent); 150W dimmable CFL/LED. The Dimmer
is designed only for use with permanently installed fixtures.
Getting to know your new Z-Wave device
• Turn ON/OFF and adjust dim levels manually or remotely via the Z-Wave controller
• Can be added in multiple groups and scenes
• May be used in single pole installation or with up to two GE-Branded
Add-on switches in 3-way or 4-way wiring configurations
• Compatible with all incandescent and most dimmable CFL/LED bulbs
• Interchangeable paddle switch — white & light almond paddle in package
• Uses a standard, decorative-size wallplate for single gang installations
(wallplate not included)
• Blue LED indicates switch location in a dark room
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load,
Neutral and Ground. Traveler wire required for 3-way or 4-way installation
• This Z-Wave device has advanced features that allow you to customize
your experience. These features can only be adjusted by a Z-Wave enabled
controller that support the Z-Wave Configuration command class. For a
complete list of adjustable configurations, visit: www.ezzwave.com/config
2.
A
B
D
F
G
C
E
A. Ground (Green/Bare)
F. Top Rocker — Press & release
to turn dimmer ON, press &
B. Load (Black)
hold increases brightness
C. Line (Black)
G. Bottom Rocker — Press
D. Traveler (Red/Other)
& release to turn dimmer
OFF, press & hold to dim
E. Neutral (White)
Single, dual and triple gang boxes
When installing the In-wall Smart Dimmer in multiple gang boxes it may be
necessary to break off one or both sides of the scored tabs on the front yoke.
This will affect the electrical rating of the switch (see specifications for details).
MANUAL • MANUEL •
MANUAL
In-Wall
Smart Dimmer
Montage mural
intelligent
Gradateur
Interruptor
de pared
reductor
de
luz inteligente
Scan to view
installation guide
Balayez ce code pour
consulter le guide
d'installation.
Escanear para ver
la guía de instalación
ezzwave.com
Z-Wave
®
Certified Wireless Lighting Control
Certifié Z-Wave
®
Commande d'éclairage sans fil
Control inalámbrico para iluminación certificado por Z-Wave
®
3.
OR
OR
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/
or damage to the switch.
This device is intended for installation in accordance with the National Electric Code and
local regulations in the United States, or the Canadian Electrical Code and local regulations
in Canada. If you are unsure or uncomfortable about performing this installation consult a
qualified electrician.
Multi-switch wiring
For 3-way installations, please refer to Add-on Switch manual
Single switch wiring
Before you start; you may wish to change the paddle color to match
your wallplate or decor. Please proceed to Section 5.
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wallplate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
5. There are up to five screw terminals on the switch; these are marked
A. GROUND — Green/Bare
B. LOAD — Black (connected to lighting)
4.
Adding your device to a Z-Wave network
To remove and reset the device
1. Follow the instructions for your Z-Wave certified
1. Follow the instructions for your Z-Wave certified controller
controller to add a device to the Z-Wave network.
to remove a device from the Z-Wave network.
2. Once the controller is ready to add your device,
2. Once the controller is ready to remove your device, press
press and release the top or bottom of the wireless
and release the top or bottom of the wireless smart
smart dimmer (rocker) to add it in the network.
dimmer (rocker) to remove it from the network.
Now you have complete control to turn your fixture ON/OFF
To return your switch to factory defaults
according to groups, scenes, schedules and interactive
1. Quickly press ON (top) button three (3) times then immediately
automations programmed by your controller.
press the OFF (Bottom) button three (3) times. The LED will
If your Z-Wave certified controller features remote access, you
flash ON/OFF five (5) times when completed successfully.
can now control your fixture from your mobile devices.
Note: This should only be used in the event your network's
primary controller is missing or otherwise inoperable.
DO NOT RETURN THIS
PRODUCT TO THE STORE
STOP
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our tech support team
at 1-800-654-8483, (option 1) Monday–Friday, 7AM–8PM CST.
For the most up-to-date product support, accessories, electronic (PDF)
format manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez
avec notre équipe de soutien technique au 1-800-654-8483,
option 1, du lundi au vendredi, de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels en
format électronique (PDF) et plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo
técnico al número: 1-800-654-8483, opción 1 de lunes a viernes,
de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES:
CONTROL DE EQUIPOS ELECTRODOMÉSTICOS:
CAUTION: TO REDUCE THE RISK OF OVERHEATING
PRECAUCIÓN: A FIN DE DISMINUIR EL RIESGO DE
AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO
RECALENTAMIENTO Y DE POSIBLES DAÑOS EN LOS
NOT INSTALL TO CONTROL A RECEPTACLE, A MOTOR-
DEMÁS EQUIPOS, NO INSTALAR PARA CONTROLAR
OPERATED APPLIANCE, A FLUORESCENT LIGHTING
APARATOS QUE FUNCIONAN A MOTOR, ARTEFACTOS
FIXTURE, OR A TRANSFORMER SUPPLIED APPLIANCE.
DE ILUMINACIÓN DE LUZ FLUORESCENTE O APARATOS
ALIMENTADOS CON TRANSFORMADORES.
• ONLY USE TO CONTROL INCANDESCENT
OR DIMMABLE CFL/LED BULBS
• USAR EXCLUSIVAMENTE PARA
CONTROLAR BOMBILLAS CFL/LED
• DO NOT EXCEED RATINGS
INCANDESCENTES O ATENUABLES
• DO NOT USE TO CONTROL ANY DEVICE WHERE
• NO SUPERE LOS VALORES NOMINALES ELÉCTRICOS
UNINTENDED OPERATION COULD CAUSE UNSAFE
CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
• NO USAR PARA CONTROLAR DISPOSITIVOS
• FOR INDOOR USE ONLY
• USE SOLAMENTE EN INTERIORES
AVERTISSEMENT
NOT FOR USE WITH MEDICAL OR
LIFE SUPPORT EQUIPMENT
RISQUE D'INCENDIE
Z-WAVE ENABLED DEVICES SHOULD NEVER BE USED TO
RISQUE DE CHOC ÉLECTRIQUE
SUPPLY POWER TO, OR CONTROL THE ON/OFF STATUS
RISQUE DE BRÛLURES
OF MEDICAL AND/OR LIFE SUPPORT EQUIPMENT.
COMMANDE DES APPAREILS:
NE PAS UTILISER AVEC UN ÉQUIPEMENT
ATTENTION: POUR RÉDUIRE LE RISQUE DE
MÉDICAL OU DE SURVIE
SURCHAUFFE ET DE DOMMAGES POSSIBLES À
LES DISPOSITIFS COMPATIBLES AVEC LA TECHNOLOGIE
D'AUTRES APPAREILS, NE PAS INSTALLER POUR
Z-WAVE NE DEVRAIENT JAMAIS ÊTRE UTILISÉS POUR
COMMANDER UN APPAREIL ACTIONNÉ PAR MOTEUR,
ALIMENTER OU COMMANDER LA MISE EN MARCHE OU
UN APPAREIL D'ÉCLAIRAGE FLUORESCENT OU UN
L'ARRÊT DE L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
APPAREIL ALIMENTÉ PAR UN TRANSFORMATEUR.
• UTILISER SEULEMENT POUR COMMANDER
SE PROHÍBE SU EMPLEO EN EQUIPO MÉDICO
LES AMPOULES À DEL ET FLUOCOMPACTES À
INCANDESCENCE OU À INTENSITÉ RÉGLABLE
O EQUIPO PARA EL MANTENIMIENTO
DE LAS FUNCIONES VITALES
• NE PAS DÉPASSER LES
CARACTÉRISTIQUES NOMINALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN USAR
PARA SUMINISTRAR ENERGÍA ELÉCTRICA AL EQUIPO
• NE PAS UTILISER POUR COMMANDER DES
MÉDICO O AL EQUIPO PARA EL MANTENIMIENTO DE
APPAREILS POUR LESQUELS UN FONCTIONNEMENT
FUNCIONES VITALES, NI PARA CONTROLAR EL ESTADO
IMPRÉVU POURRAIT ENTRAÎNER DES
DE ENCENDIDO O APAGADO DE DICHOS EQUIPOS.
CONDITIONS DANGEREUSES (LAMPE À RAYONS
INFRAROUGES, LAMPE SOLAIRE, ETC.)
• POUR UTILISATION INTÉRIEURE UNIQUEMENT
14294
ZW3005
B
D
E
A
C
C. LINE (Hot) — Black (connected to power)
D. TRAVELER — Red/Other (only in 3-way installations)
E. NEUTRAL — White
Match these screw terminals to the wires connected to the existing switch.
6. Disconnect the wires from the existing switch. Be careful to label
wires according to the previous terminal connection.
Observe Important Wiring Information
IMPORTANT! This switch is rated for and intended to only be used with copper wire.
Wire Gauge Requirements
Use 14 AWG or larger wires suitable for at least 80° C for supplying Line
(HOT), Load, Neutral, Ground and Traveler connections.
Wire strip length:
For attachment to screw terminals: strip insulation 1" (25mm)
7. For attachment using the enclosure's holes: strip insulation 5/8" (16mm)
UL specifies that the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).
8. Connect the green or bare copper ground wire to the GROUND terminal.
9. Connect the black wire that goes to the light to the terminal marked LOAD.
10. Connect the black wire that comes from the electrical service
panel (Hot) to the terminal marked LINE.
11. Connect the white wire to the neutral terminal (use a jumper wire if needed).
Note: The Traveler terminal is only used for 3-way or 4-way wiring and should remain
insulated if the switch is being installed in a 2-way system (one switch & one load).
5.
Z-WAVE INTEROPERABILITY
This product can be added and operated in any
Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other
applications. All non-battery operated nodes within
the network will act as repeaters regardless of
vendor to increase reliability of the network.
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a period of
two years from the original date of consumer purchase. This warranty is limited to the repair or
replacement of this product only and does not extend to consequential or incidental damage to other
products that may be used with this product. This warranty is in lieu of all other warranties, expressed
or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damage, so the above limitations may not apply
to you. This warranty gives you specific rights, and you may also have other rights which vary from
state to state. Please contact Customer Service at 800-654-8483 (option 1) between 7AM – 8PM CST
or via our website (www.byjasco.com) if the unit should prove defective within the warranty period.
GARANTIE
JASCO Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l'achat original par l'acheteur. Cette garantie se
limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas applicable aux
dommages indirects ou accessoires survenus sur d'autres produits utilisés avec ce produit. Cette
garantie se substitue à toute autre garantie expresse ou implicite. Certains États ne permettent pas
de restrictions quant à la durée d'une garantie implicite ou permettent l'exclusion ou la limitation des
dommages indirects et accessoires; il se peut, par conséquent, que cette garantie ne s'applique pas
dans votre cas. Cette garantie vous confère des droits juridiques précis; vous pouvez jouir d'autres
droits qui peuvent varier d'un État à l'autre. Veuillez communiquer avec le service à la clientèle au
1-800-654-8483 (option 1) entre 7 h et 20 h (heure normale du Centre) ou par l'intermédiaire de
notre site web (www.byjasco.com) si l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
JASCO Products garantiza que este producto está libre de defectos de fabricación durante
un periodo de dos años a partir de la fecha original de compra por parte del consumidor. Esta
garantía se limita a la reparación o sustitución de este producto solamente y no se extiende a
daños derivados o accidentales causados a otros productos que se usen con esta unidad. Esa
garantía remplaza a todas las demás garantías expresas o implícitas. Algunos estados no autorizan
limitaciones en cuanto a la duración de una garantía implícita ni permiten la exclusión o limitación
por daños accidentales o derivados; por lo tanto, puede que las anteriores limitaciones no apliquen
en su caso. Esta garantía le da a usted derechos específicos, y otros que usted puede tener y
que varían según el estado en el que usted reside. Si la unidad resultare defectuosa dentro del
periodo de garantía, comuníquese por favor con Atención al Cliente en el 800-654-8483 (opción
1) entre 7 y 20 h, Hora del Centro, o a través de nuestro sitio de internet (www.byjasco.com).
JASCO Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW3005
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.4 / 916 MHz
Maximum Loads: 600W, 2-gang 500W or 3-gang 400W incandescent, 150W CFL/LED
Range: Up to 150 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW3005
Tension : 120 VCA, 60 Hz.
Signal (fréquence) : 908.4 / 916 MHz
Charges maximales : 600 watts, 2 compartiments 500 W,
3 compartiments 400 W lampes à incandescent 150W CFL/LED
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant jusqu'à
150 pi (45,72m).
Plage de températures de fonctionnement : de 32 à 104 °F (de 0 à 40 °C).
Utilisation intérieure uniquement.
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de changements sans
préavis.
ESPECIFICACIONES:
ZW3005
Alimentación: 120 VAC, 60 Hz.
Señal (frecuencia): 908.4 / 916 MHz
Cargas máximas: 600 W, Caja para 2 conexiones 500 W,
Caja para 3 conexiones 400 W sólo las lámparas incandescente 150 W CFL/LED
Alcance: Hasta 150 pies (45,72m) en línea de visión directa entre el control remoto inalámbrico y el módulo
receptor Z-Wave más cercano.
Rango de temperatura de funcionamiento: 32-104 °F (0-40 °C).
Para uso en espacios interiores solamente.
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto.
Out to Light (Load)
B
A
D
E
C
From Breaker Box
12. Insert dimmer into the switch box being careful not to pinch or crush wires.
13. Secure the dimmer to the box using the supplied screws.
14. Mount the wallplate.
15. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic Operation
The connected light can be turned ON/OFF and adjust dim levels in two ways:
1. Manually from the front panel of the In-Wall Dimmer.
2. Remotely with a Z-Wave Controller.
Manual Control
The front panel rocker dimmer allows the user to:
Turn ON/OFF the connected fixture.
1. To turn the connected fixture ON: Press and release the top of the rocker.
2. To turn the connected fixture OFF: Press and release the bottom of the rocker.
Adjust Dim Levels
1. To increase brightness: press and hold the top of the rocker.
2. To decrease brightness: press and hold the bottom of the rocker.
Disable / Enable LED
1. Press UP three (3) times then quickly press and release DOWN one (1) time.
2. Repeat to disable/enable LED.
To change color of the paddle
The GE-branded Add-on switch is
2.
required for Multi-Switch 3-way
This step is optional. Before you start you
or 4-way installations.
may want to change the color of the paddle
Connecting the traveler terminal of this
to match your wallplate or decor.
switch to a standard, non-GE-branded switch
1. Lift the air gap tab at the base of the paddle.
will cause damage or result in improper
2. Push side tabs in on one side and then the other
function. If this switch is a part of a 3-way
or 4-way multi-switch installation, do not
to release paddle. Lift the cover up and off.
connect the traveler wire or apply power
3. Simply put the new paddle onto the switch
until GE-branded Add-on switches are
by inserting the air gap and side tabs
1.
correctly installed. For more information
and snapping securely into place.
on 3-Way or 4-Way installations, view the
Once this step has been completed
manual or quick-start guide that comes
please return to Section 3.
with the GE-branded Add-on switch.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Multi-level Switch report
• Association Group 2 supports Basic Set and is controlled with the local load
• Association Group 3 supports Basic Set and is controlled by pressing the On or Off button
• Each Association Group supports 5 total nodes
NOTE: Actual performance of any CFL or LED will vary from bulb type to bulb type and among
different manufacturers. It is important to note that only bulbs that have been designed as
dimmable should be used on a dimmer. To find out if your bulb is dimmable, please check the
package, the bulb itself, or call the bulb manufacturer directly.
For a complete list of recommended CFL/LED bulbs for this and other Z-Wave products from
Jasco, please vist www.ezzwave.com

Publicidad

loading

Resumen de contenidos para GE Z-Wave ZW3005

  • Página 1 • Turn ON/OFF and adjust dim levels manually or remotely via the Z-Wave controller • Can be added in multiple groups and scenes • May be used in single pole installation or with up to two GE-Branded Add-on switches in 3-way or 4-way wiring configurations •...
  • Página 2 • Peut être inclus dans de nombreux groupes et de nombreuses scènes • Peut être utilisé en installation unipolaire ou avec un ou deux interrupteurs supplémentaires GE dans des configurations de câblage à trois ou quatre voies • Compatible avec toutes les lampes incandescentes et la plupart De la boîte des disjoncteurs...

Este manual también es adecuado para:

Z-wave 14294