Two Note Mechanical Door Chime
Installation Instructions and Drill Template.
Read and Save these Instructions.
• The non-electric chime mounts directly
through the door and will accommodate
door thicknesses of 3/4" to 2".
LOCATING THE DOOR CHIME
1. Mount the chime in the center of the door
approximately 4 1/2 feet to 5 feet above
the floor. Note: Be sure there are no
obstructions on the inside of the door to
interfere with the chime's baseplate.
2. Using the template provided, mark the
location of the mounting holes parallel
to the edge of the door (see Figure 1).
Note: It is important that the holes are
parallel to the edge of the door for proper
operation of the chime.
3. Drill one 1" hole parallel to edge of
door (push button shaft hole 1" DIA.
in mounting template).
4. Drill three pilot holes using a 1/16" drill
bit.
Door Edge
Name Card
Name Card Holder
Metal Trim
Trim Screw
Figure 1 - Attaching Push Button Assembly to Door
Please note: this door chime works best for smaller homes, apartments, studios, or offices.
Door Viewer Installation Instructions for Model MCH2V
1. Mark the center of the door where you want to install the viewer using a measuring tape. Make sure that the height of the viewer is convenient for you.
2. Use a 9/16-inch spade bit to drill a hole where you marked the door. This viewer will work with doors that are between 1 5/16 inches and 2 inches thick.
3. Take the bit and line it up with the edge of the door (until the tip of the bit is just past the interior surface) and wrap tape around the bit's shaft to mark
the correct depth for drilling the hole.
4. Wood doors could splinter when drilling. To keep from splintering the wood, start drilling at a 90-degree angle slowly from the exterior side of the door
first, and stop when the tape line is reached. A pilot hole should be created on the interior side of the door.
5. Use the pilot hole you just created to drill back out from the interior side to complete the hole.
6. Insert the lens (the piece with threads on the outside) into the hole from the exterior side of the door. Then, insert the barrel (the piece with threads on
the inside) into the hole from the interior side and hand-thread the viewer together.
7. Apply a bead of silicone sealant around the lens to help seal out moisture if you don't have a storm door or overhang.
8. Tighten with a coin. The viewer should be flush with the door and snug.
PUSH BUTTON ASSEMBLY
See Figure 1 for push button assembly.
Note: If push button assembly is located
in an area that is exposed to rain, caulk
around the 1" holes before attaching push
button to door.
ATTACHING PUSH BUTTON
ASSEMBLY
1. Remove metal trim screw, metal trim,
name card holder, and name card from
push button assembly to locate mounting
holes (see Figure 1).
2. Insert push button shaft into pre-drilled
until push button assembly is flush
against door face. Attach using the
three mounting screws provided (see
Figure 1).
3. Print or type name and address on name
card (provided). Place card in holder
with printing visible through front of card
holder.
4. Place metal trim over push button as-
sembly and name card holder. Secure
trim with trim screw (see Figure 1).
1" Shaft Hole
1/16" Pilot Hole
Push Button Shaft
Push Button Assembly
Mounting Screw
It may be difficult to hear this chime from further than 30 feet away.
MOUNTING CHIME ASSEMBLY
1. Position chime assembly over push
button shaft (see Figure 2).
2. Verify chime assembly is parallel to
edge of door.
3. Attach the top and bottom of chime
assembly securely using mounting
screws provided (see Figure 2).
OPERATION
1. Verify door chime operation by pressing
push button. The chime will sound two
(2) notes.
2. If door chime does not operate properly,
check push button and chime assemblies.
Both assemblies must be parallel to
the door edge for proper chime operation.
3. If necessary, adjust one or both as-
semblies.
Push Button
Assembly (Shown
on Outside of Door)
Cover Mounting Tab
Break Off Excess
Push Button Shaft
Chime Assembly
Mounting Screws
Figure 2 - Mounting Chime Assembly and Attaching Chime Cover
Model
MCH1 / MCH2V
ATTACHING CHIME COVER
1. To insure proper clearance when the
cover is attached, break off the excess
push button shaft. IMPORTANT: To
avoid breaking plastic chime assembly
parts, use needle-nosed pliers to hold
shaft securely while bending shaft back
and forth to remove (see Figure 2, View A).
2. Place slot in chime cover over tab on
top of chime assembly.
3. Press bottom of chime cover onto
chime assembly until cover "snaps"
into place.
Questions? Please contact us at
cs@adamaxinc.com
Needle-Nosed Pliers
Cover
View A
Mounting
Slot
Chime Cover
-1-

Publicidad

loading

Resumen de contenidos para NEWHOUSE HARDWARE MCH1

  • Página 1 Model MCH1 / MCH2V MOUNTING CHIME ASSEMBLY ATTACHING CHIME COVER 1. Position chime assembly over push 1. To insure proper clearance when the cover is attached, break off the excess button shaft (see Figure 2). 2. Verify chime assembly is parallel to push button shaft.
  • Página 2 Modelo MCH1 / MCH2V MONTAJE DEL CONJUNTO ACOPLE DE LA TAPA DE LA CAMPANA CAMPANA 1. Coloque el conjunto campana sobre el 1. Para asegurar el espacio libre correcto Campana no electrica de dos notas eje del pulsador (vea la Figura 2).

Este manual también es adecuado para:

Mch2v