electrified wires shall be constructed so as to ensure that these wires are positioned at a
minimum distance of 150 mm from the vertical plane of the non-electrified wires. The barbed
wire and razor wire shall be earthed at regular intervals.
• Follow the installation instructions regarding earthing.
• A distance of at least 10 m shall be maintained between the energizer earth electrode and any
other earthing system connected parts such as the power supply system protective earth or
the telecommunication system earth.
• Connecting leads that are run inside buildings shall be effectively insulated from the earthed
structural parts of the building. This may be achieved by using insulated high voltage cable.
• Connecting leads that are run underground shall be run in conduit of insulating material or else
insulated high voltage lead-out cable shall be used. Care must be taken to avoid damage to the
connecting leads due to the effects of animal hooves or tractor wheels sinking into the ground.
• Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.
• Connecting leads and electric animal fence wires shall not cross above overhead power or
communication lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such a crossing
cannot be avoided it shall be made underneath the power line and as nearly as possible at
right angles to it.
• If connecting leads and electric animal fence wires are installed near an overhead power line,
the clearances shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line Voltage V
Less than or equal to 1 000
Greater than 1 000 and less than or equal to
33 000
Greater than 33 000
• If connecting leads and electric animal fence wires are installed near an overhead power line,
their height above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projection of the outermost conductors of the
power line on the ground surface, for a distance of:
2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
-
15 m for power lines operating at a nominal voltage exceeding 1 000 V.
-
4
Gallagher 3E5315 S6 Lithium Solar Fence Energizer User Manual
Clearance m
3
4
8