Troubleshooting - Hozelock 2220 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
GENERAL INFORMATION
GB
- This product is not suitable for supplying
drinking water.
- Threaded water connections are suitable for
hand tightening only.
- This product is suitable for use on mains water
up to max 10 bar pressure.
- This product can be used on an outdoor water
butt that is higher than the area to be watered
(a gravity fed system).
Please follow the instructions to make sure that
you get the most from your timer for simple and
efficient watering.
INSTALLING THE BATTERIES
You must use Alkaline or Lithium batteries -
alternatives will result in incorrect operation.
1. Remove the front panel – pull the panel away
from the body of the timer.
2. Insert two 1.5V 'AA' (LR6) Alkaline batteries.
(Check + and – terminals are correct.).
IMPORTANT: Rechargeable batteries must not
be used.
3. The valve will open and close to check that it
is closed.
Note: Replace batteries each season. (maximum
12 months use)
HOW TO PROGRAMME THE TIMER
There are two watering operations - AUTOMATIC
and MANUAL.
AUTOMATIC WATERING
1. Turn the dial fully clockwise to START TIME at
the actual desired start time
(e.g. To start watering each day at 15H00 you
must set your SELECT water time when the
actual time of day is 15H00).
The timer has now memorised the START TIME
until it is reset and will operate every day at this
time. When you remove the batteries the start
time is erased so only remove the batteries when
you need to replace them.
Refer to the section CHANGING THE BATTERIES.
2. Turn dial anti-clockwise to any of the 16
programs. The LED light will flash 3 times
and the timer will now automatically run the
selected program repeatedly until a new option
is selected. The Start time does not need to
be reset when a different program is selected,
simply rotate the dial to the new position.
PROGRAM DESCRIPTION
Every 24 Hours
2 minutes
(Daily)
5 minutes
10 minutes
20 minutes
30 minutes
60 minutes
Every 6 Hours
2 minutes
5 minutes
Every 12 hours
2 minutes
5 minutes
10 minutes
Every 48 Hours
20 minutes
60 minutes
Every 72 Hours
30 minutes
60 minutes
Every 7 days (once a week)
60 minutes
MANUAL WATERING
Note: You do not need to adjust the Automatic
watering dial to water immediately.
MANUAL ON
Press the water now button on the front panel
(the panel must be attached to the valve).
4
Water will flow for 60 minutes maximum or until
it is turned off. The LED will flash green when
watering occurs.
Note: After 60 minutes water shuts off
automatically. Automatic watering will continue
normally unless the dial is turned to the OFF
position.
MANUAL OFF
Press the water now button again at any
time and the valve will close. The led will stop
flashing.
Note: To protect battery life the water controller
can only be turned on and off a maximum of 3
times in one minute.
CONNECTING THE TIMER TO THE TAP
Use supplied adaptors if required.
Hand tighten firmly to ensure no leaks. Do not
use a wrench or other tool to tighten the nuts
as this can permanently damage the plastic
components
BATTERY CHECK FUNCTION
BATTERY CHECK FUNCTION
To check the status of the installed batteries simply
press and hold down the water now button.
GREEN LED
BATTERIES ARE OK
RED LED
BATTERIES NEED TO BE
REPLACED WITH NEW ONES.
See "CHANGING THE
BATTERIES" section.
FAILURE PREVENTION MODE
A built in safety feature detects when the
battery levels have dropped to a level that could
fail whilst the valve is open and result in wasting
water.
The safety mode prevents the controller
from turning on until the batteries have been
replaced.
The LED indicator light will flash red when the
failure prevention mode has been activated.
The water now function will also not operate
until the batteries have been replaced.
CHANGING THE BATTERIES
When changing the batteries remove the old
ones then wait 20 seconds before putting the
new batteries in.
PROGRAM SELECTION STICKER
Your Select Timer is supplied with
stickers to help you select the correct
programs. Attach the sticker to the
body behind the front panel as shown.

TROUBLESHOOTING

PROBLEM
SOLUTION
Valve opens and closes
Your Select Timer has
when batteries are first
detected low battery
inserted but then fails to
power. Replace with new
operate when watering
batteries.
manually or automatically.
The LED is flashing red
Your Select Timer has
colour
detected low battery
power. Replace with new
batteries.
Valve operates but no
Check tap is turned on.
water flows.
Valve works on manual
Set the Start Time time as
but no automatic watering.
described in the Automatic
Watering section.
LED flashes green when
Make sure the front panel
I press the water now
is fully inserted into the
button but the valve does
body.
not operate
TECHNICAL DATA
Operating Pressure
0.1 – 10Bar
Operating Temperature
1 - 55°C
Maximum water temperature
30°C
5

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido