Pull power plug of the dust extractor from the
socket outlet.
Clear away mains cable.
Remove electric tool.
The socket outlet 4 is intended for connection of an
electric tool (IR/AR mode).
To avoid excessive start-up peaks, the dust extractor
is equipped with a starting current limit (soft start).
5.1.1
Permanent filter cleaning
The dust extractor is equipped with an electro-magnet
filter cleaning system, that can be used to shake
adhering dust off the folded filter cartridges. The
folded filter cartridges are cleaned alternatively in
succession so that continuous working is guaranteed.
- Constant fill level monitoring of the filters by
differential pressure measurement for absolutely
accurate need-controlled filter cleaning during
operation.
- This guarantees a constantly high air flow during
operation, even for critical types of dust.
5.2 Hints and information
- When vacuuming dry materials, the folded filter 5
(fig. 2) must be completely dry.
- During wet vacuuming, the built-in sensor prevents
the maximum filling level in the container from
being exceeded. The device no longer vacuums
when the container is full. Switch off motor. Pull the
dust extractor plug and empty the container.
- If the sensor responds when vacuuming larger
amounts of liquid (more than one container filling),
switch off the device and empty the container.
- If the volume flow display 3 (fig. 1) lights up on
restart, this may have the following reasons:
Container, filter bag 8 (fig. 4) full.
-
Extraction hose clogged.
-
Air cross sections of the dust generator too
-
small.
On completion of work, but especially if you do not
intend to use the device for a longer period of time,
you should:
- Discharge any dirt and liquids.
- Store the extraction hose such that there are no
kinks.
- Neatly reel up the mains cable and protect it
against damage.