Tappan TGF657BFW9 Instrucciones De Instalación página 4

Estufa a gas de 36
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

36" GAS RANGE INSTALLATION INSTRUCTIONS
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
Disconnect this range and its individual shutoff
valve from the gas supply piping system during any
pressure testing of that system at test pressures greater
than 14" of water column pressure (approx. ½" psig).
Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column
(approx. ½" psig).
Back of
Range
Flexible
Connector
Flexible Connector Hookup
Figure 5
Shut-Off Fitting
Union
Solid Pipe Hookup
Figure 6
1/2"
Close Nipple
Recommended Shut-Off
Location
Back of
Range
½" Nipple
3
6
/
"
8
7
¾ "
1
/
"
16
11 ½"
3 ¾ "
End of
Counter
Pressure
Top
Regulator
TOP VIEW
Solid Pipe Hookup Detail
5. LP/Propane Gas Conversion
A. Pressure Regulator Conversion
L.P.
Do Not Remove the Pressure Regulator
Remove cap-screw and snap out the nylon gas
indicator by pushing it sideways. Turn the nylon gas
indicator for type gas (Natural or LP) and snap it back
in the cap-screw. Put cap-screw back on gas
regulator.
4
5
2
/
"
8
Wall
± ¼ "
Manifold
6 "
Floor
FRONT VIEW
Figure 7
NAT .
Cap Screw
Figure 8