QUICKBOX box
Description
Upper protection for secondary
1
7
pipework
Bottom protection for secondary
2
8
pipework
Terminal plate for wall mounting
3
9
and positioning
Key for opening/closing the
4
10
cover
Removable net for allowing the
5
11
mortar to set
Base
6
12
9
8
6
1
3
2
4
5
55, 70 and 85 cm
Available dimension:
1
Positioning with easy fastening
A
(GB) After choosing the most suitable position and making an
opening in the wall for inserting the box, use the middle brack-
ets (bring them to the end stop until they click) to position the
edge of the box at a distance of 1 cm from the hollow brick.
This distance corresponds to the thickness of the plaster.
These brackets will make it possible to align and to fix the bot-
tom of the box to the wall temporarily using nails or screws.
N.B. If a connecting hole is drilled, it is possible to use the
grids on the bottom of the box to let the mortar set.
B
(GB) Afterwards apply rapid cement onto the 4 brackets, on
the corners and onto the setting grids placed on the bottom
of the box in order to fix the box firmly to the wall.
Before carrying out these operations, mount the protection
supplied to prevent the inside of the box from getting dirty.
foglietto 55 cm GB.indd 1
ASSEMBLY INSTRUCTION
Examples of coupling between manifold
!
kits and the box
Manifold Polymers
Wall protection
Cover
Fixing screws for
cover
Lower bracket
Higher bracket
Bracket screws for
manifolds fixing
Brass Manifold
7
12
11
10
2
Assembly and connection
B
(GB) Fix the manifold groups (delivery and return) using
A
the moving clips placed in the guides which when neces-
sary can be moved to right or left for correct positioning.
(GB) If the opening of the wall is a through opening, the
B
protection supplied must be mounted behind the second-
ary pipework.
C
(GB) To facilitate the connection of secondary pipework
C
to the manifolds, the upper profile at the base of the box
must be removed. This will make it possible to insert the
"extractable" masonry protections.
4
Masonry protection shell
A
B
C
(GB) When the system is con-
nected, close the compartment
of the box using the specific
protection, before plastering the
unfinished wall.
55
cm
BOX
Small overall dimensions,
!
depth of built-in box
adjustable from 8 to 10 cm.
8 cm
A
1 cm
B
C
(GB) Partitioning element 8 cm.
A
(GB) 1 cm plaster on both sides.
B
(GB) Removable mortar setting grid (thickness
C
2.5 mm.) (fastening with anchorage teeth).
3
Positioning and coupling
1
(GB) Place the dovetail guide of the brackets in the open-
ings made on the bottom of the box (1). Then simply move
the manifold group to the right in order to fix it to the box,
using brackets.
Positioning layout of the
terminal manifold group
inside the box, using
brackets
Four slits for the inser-
tion of the collectors in
the guides to accom-
modation worthless
ball and exhaust unit
NUMER OF
TERMINALS
LAYOUT OF THE
OPENINGS
Installation of the cover
5
(GB) When the wall
A
rendering is completed,
fix the cover using the
A
standard RBM screws
supplied.
2
1
2
3
4
20-12-2010 12:24:50