Mount to Wall
Solid Concrete and Concrete Block
2-1
Level wall plate [02] and mark hole locations
[02]
2-2
Drill pilot holes as illustrated
2-3
Insert anchors [05]
2-4
Tighten lag bolts [03]
[04]
[03]
8
damage!
sure the anchors [05] are seated fl ush with the concrete surface.
[05]
Tighten lag bolts [03] only until the washers [04] are pulled fi rmly
[05]
against the wall plate [02].
the lag bolt. To avoid potential injuries or property damage: DO NOT
over-tighten the lag bolts [03].
[02]
CAUTION:
Avoid potential personal injuries and property
Mount the wall plate [02] directly onto the concrete surface.
Minimum solid concrete thickness: 203 mm (8 in.).
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in.).
CAUTION:
To avoid potential injuries or property damage:
Pilot holes MUST be drilled to a depth of 75 mm (3 in.) using a
10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
75 mm
(3 in.)
CAUTION:
To avoid potential injuries or property damage: Be
CAUTION:
Improper use could reduce the holding power of
13 mm
10 mm
(1/2in.)
(3/8 in.)