Installation Instructions – Galleon / Galleonaire
Photocontrol Orientation (If Equipped)
N
otee:
The orientation procedure is only required for
photocontrols which specifically require the cell to
be aimed north. Otherwise pre-selected factory
orientation will function properly. Follow the
directions recommended by the photocontrol supplier
for proximity to light sources. Lighted signs, building
surface reflection, floodlights, tree branches, etc.
may affect final position of the photocontrol.
1.
Loosen the two screws to allow rotation of the
receptacle.
2.
Insert screwdriver into center slot and rotate receptacle
until indicator arrow points north.
3.
Retighten screws.
4.
Insert the photoelectric control (or shorting cap) into
receptacle and twist into locked position.
N
otee:
The photocontrol (not included) must contain a soft,
resilient gasket fastened to the bottom surface to
assure a proper weather seal between the control
and the receptacle.
Bi-Level Switching (If Equipped)
For Bi-level switching, the input leads to the fixture will be
independently labeled to indicate dimming preferences as
appropriate (as defined by the order requirements). Two
separate supply lines of line voltage, neutral and ground
must be connected to the fixture leads to enable the bi-level
switching functionality of the fixture.
Maintenance
A regular maintenance schedule should be followed to
retain optimal light output and thermal performance. Optical
lens cleaning should be performed with a clean dry cloth to
remove any dust or other contaminants. Additional cleaning
can be performed with non-abrasive acrylic cleansing
solution.
4
COOPER LIGHTING SOLUTIONS
IB500021EN
Installation instructions