H-8271, H-8272
H-8273, H-8274
SERVICE KIT FOR INDUSTRIAL
SHRINK SYSTEM
TOOLS/SUPPLIES NEEDED
Flat Head Screwdriver
1.
Remove worn silicone rubber pad from metal channel.
2. Place new silicone rubber pad (A) inside metal
channel (B). (See Figure 1)
NOTE: Trim to fit.
B
Figure 1
3. Clean new silicone rubber pad with rubbing alcohol
and a clean cloth.
4. Apply the dark brown 10 mil Teflon Tape (C) to top of
silicone rubber pad (A). (See Figure 1)
CAUTION! Unplug shrink wrap system before
replacing nichrome wire.
1.
Locate and remove black plastic screw (G) on right
side of the sealing arm. Remove black plastic end
cap (H). Remove white plastic insulator sleeve (I).
(See Figure 2)
PAGE 1 OF 6
Phillips Head Screwdriver
TEFLON TAPE REPLACEMENT
C
A
NICHROME WIRE REPLACEMENT
1-800-295-5510
uline.com
Rubbing Alcohol
5. Remove worn tape from flexboard (D) on bottom of
sealing arm. (See Figure 2)
Shrink Wrap System Arm
D
NOTE: If there is a yellow or brown film residue
built up on the flexboard, it will need to be
scraped off before applying the new Teflon tape.
6. Apply light brown 3 mil Teflon tape to flexboard over
nichrome sealing wire (F).
7.
Extra pieces of Teflon tape have been included for
future use.
2. Locate the phenolic
assembly and remove
from arm slot by pulling
downward. (See Figure 3)
3. Remove the screw that
secures the wire to the
assembly. (See Figure 3)
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
I
H
F
Figure 2
Figure 3
Screw
Phenolic
Assembly
0621 IH-8271
G