Function
Pin
1
0 V DC (-)
2
DC input
UL: DC power to be supplied by a UL 294, UL 293 or UL 603 listed power supply, depending on
application, with appropriate ratings.
Backup battery input connector
For a backup solution using a battery with built-in charger. 12 V DC input.
UL: The connector has not been evaluated by UL.
Important
When the battery input is used, an external 3 A slow blow fuse must be connected in series.
Function
Pin
1
0 V DC (-)
Battery input
2
AXIS A1601 Network Door Controller
Notes
For powering controller when not using
Power over Ethernet.
Note: This pin can only be used as
power in.
Notes
For powering the door controller when
other power sources are unavailable.
Note: This pin can only be used as
battery power in. For connection to UPS
only.
27
Specifications
0 V DC
10.5–28 V DC, max 36 W
Specifications
0 V DC
11– 13.7 V DC, max
36 W