COMFORT - Tech
EN
Fiamma declines all liability for any personal injury or damage due to mounting or inability to use
the product.
Product installation is to proceed according to the mounting instructions; the product may not be
modifi ed or altered in any way.
Mount the pump on a solid surface and in a position comfortable for fi lter cleaning and routine
maintenance. The pump can be installed in any position, in the event of installation in vertical
position put the motor above the hydraulic part.
Mount the pump near the water tank in order to obtain the best performance.
Despite the anti-vibration base kit is recommended to connect input and output of the pump
through a min. 0.5mt. and diameter 1/2 "(13mm.) fl exible pipe in order to attenuate the vibrations
that otherwise the pump would send to the hydraulic system causing noise.
For proper operation of the pump install at the entrance of the same the Fiamma fi lter or a fi lter
with a 13 mm. minimum passing and not less than 36 mesh.
The installation of the Fiamma A20 expansion tank (02478-01-) within the fi rst meter of the
implant optimizes and stabilizes the performance of the product.
The pump is designed only for intermittent use and for contact with drinking water, any other use
may cause undesired operation.
For safety reasons, it is advisable to always disconnect the negative terminal from the batteries on
the vehicle and then work without power during installation.
It is suggested to connect the power cable to the fuse box or to the terminal board and not
directly to the battery.
Prepare for the electrical connection a dedicated circuit with a cable of 16AWG 1.5mm ² minimum
section protected by 7.5 A and 15 A switch located on the positive cable.
Installing an oversized fuse can cause overheating which can result in a short circuit or malfunction
of the entire electrical equipment.
Choose the safest and shortest installation for the power cable. Reduce the length of the power
cable as necessary.
Use only cable clamps suitable for the diameter of the power cable for connection to the terminal
board.
If incorrect terminals are used, this could cause a voltage drop and increase the formation of heat
on the terminal.
When using for the fi rst time, it's advisable to proceed with the sanitation so as to remove any
processing waste.
Check periodically the cleaning of the inlet fi lter or in the event of low fl o.
Clean the fi lter periodically (at the start and end of the season).
During winter storage if outdoor temperatures are expected <0 ° C it is absolutely necessary to
drain the entire plumbing system, especially the pump by disconnecting the vacuum hose and
making it run for a few minutes as long as no water comes out from all the taps .
To ensure the proper operation of the pump and of the plumbing system is recommended to
make the sanitization of the same at least once a year or after a long period of non-use of the
product.
Periodically check the tightness of the hydraulic components that vibrations may have loosened.
The manufacturer will not be held responsible for claims for damages resulting from the following:
- Defective installation or connection of the product.
- Damage to the product caused by mechanical infl uences and overvoltage.
- Alterations on the device without the express authorization of the manufacturer.
- Use of the product for other purposes not described in the operating manual.
7