INTELLIGENT AUTOMATIC
INTELLIGENT AUTOMATIC
BATTERY CHARGER
BATTERY CHARGER
OPERATION MANUAL
OPERATION MANUAL
WARNING
Please wear proper safety gear while working.
Enjoy your work
FAULT CODES
1.No clamps connected
F1
2.Short circuit
3.Reverse polarity connection
F2
Loose clamps during charging
F3
Battery voltage is too high
F4
Bad Battery
MAINTENANCE
● After each use, clean the battery charger clamps be sure to remove any battery fluid that will cause
corrosion of the copper clamps. Clean the outside case of the charger with a soft cloth and, if necessary,
mild soap solution.
● Keep the charger cords loosely coiled during storage to prevent damage to the cords.
● Do not use the charger if cords or clamps have been damaged in any way.
● If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or
qualified person in order to avoid a hazard.
Warning:
Do not use the product in bathroom or other damp places or places near the water.
Do not remodel or dismantle the device.
Keep the product away from the children.
Do not hit or throw the product.
Keep the product away from fire.
Do not charge the device with higher voltage.
°C
The temperature should be kept between -20°C to 50°C when the device is being charged.
1
Disconnect the main cable before connecting or disconnecting the clamps.
2
9DS31
NO.
1
INTRODUCTION
● Fully automatic multi-cycle switch mode chargers and maintainers designed for charging a variety of
batteries: SLA, WET, AGM/GEL and VRLA.
● Chargers will recover slightly sulphated batteries and may rescue drained batteries.
● The digital display lets you know exactly how the charger is performing and indicates the
charging or maintenance phase and battery voltage.
● Suitanle for motorcycles and cars.
SPECIFICATIONS
KT NO.
9DS311
9-Cycle 6/12V
Type
AC 220~240
Input
50/60Hz
Output
6/12V
Input Current
0.48A
Charging Current
4A
Ambient Temperature
-20°C ~ 50°C
Weight
0.66KG
OPERATION
1. Connect the (+) red clamp to the positive (+) battery post and connect the (-) black clamp
to the negative (-) battery pos.
2. Plug the charger into the power supply and switch on and the LCD screen will light up.
3. Press the "MODE button" to select charging program. Settings are made by pressing the "
MODE-button" and stepping forward by pressing the button one step at a time, releasing
the button when the required mode is reached.
4. Stop charging at any time by disconnecting the mains cable from the wall socket.
NOTE: the charger should be connected to the battery before connecting to the mains supply.
To select charging mode or re-set during charging
Mode
0.0
v
Battery voltage
Recon
Battery Repairing
Slow
12V Slow mode:14.4V/1.0A
0.0
v
This mode is normally used for all types of 12V batteries<20Ah
12V
Fast
12V Fast mode: 14.4V/4.0A
0.0
v
This mode is normally used for all types of 12V batteries<80Ah
12V
Winter mode:14.7V/4.0A
0.0
v
This setting is recommended for batteries at temperatures below 5°C.
12V
It is also recommended for many AGM batteries
Mode 7.5V/4.0A
0.0
v
6V
This is normally used for all types of 6V batteries.(Only applies to 9DS311)
Charging Status indicator
FULL
This will show the charging status. When the battery is fully charged,
the word "FULL" will show up
NOTE: This charger has a Memory Function. It will return to last mode you chose, next time the charger is connected.
No.
Description
No.
1
CLAMP CLIP
7
2
UPPER COVER
8
3
BOTTOM COVER
9
4
SEALING RING
10
5
PCB
11
6
CONTROL PCB
customer service e-mail : service@kingtony.com
9DS312
9-Cycle12V
AC 220~240
50/60Hz
12V
0.6A
8A
-20°C ~ 50°C
0.80KG
Description
AC PLUG WITH CABLE
POSITIVE & NEGATIVE CLAMP ASS'Y
SCREW 3x16mm
SCREW 3x12mm
SCREW 3x6mm
899DS31-KT
297x210mm