Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

INTELLIGENT AUTOMATIC
INTELLIGENT AUTOMATIC
BATTERY CHARGER
BATTERY CHARGER
OPERATION MANUAL
OPERATION MANUAL
WARNING
Please wear proper safety gear while working.
Enjoy your work
FAULT CODES
1.No clamps connected
F1
2.Short circuit
3.Reverse polarity connection
F2
Loose clamps during charging
F3
Battery voltage is too high
F4
Bad Battery
MAINTENANCE
● After each use, clean the battery charger clamps be sure to remove any battery fluid that will cause
corrosion of the copper clamps. Clean the outside case of the charger with a soft cloth and, if necessary,
mild soap solution.
● Keep the charger cords loosely coiled during storage to prevent damage to the cords.
● Do not use the charger if cords or clamps have been damaged in any way.
● If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or
qualified person in order to avoid a hazard.
Warning:
Do not use the product in bathroom or other damp places or places near the water.
Do not remodel or dismantle the device.
Keep the product away from the children.
Do not hit or throw the product.
Keep the product away from fire.
Do not charge the device with higher voltage.
°C
The temperature should be kept between -20°C to 50°C when the device is being charged.
1
Disconnect the main cable before connecting or disconnecting the clamps.
2
9DS31
NO.
1
INTRODUCTION
● Fully automatic multi-cycle switch mode chargers and maintainers designed for charging a variety of
batteries: SLA, WET, AGM/GEL and VRLA.
● Chargers will recover slightly sulphated batteries and may rescue drained batteries.
● The digital display lets you know exactly how the charger is performing and indicates the
charging or maintenance phase and battery voltage.
● Suitanle for motorcycles and cars.
SPECIFICATIONS
KT NO.
9DS311
9-Cycle 6/12V
Type
AC 220~240
Input
50/60Hz
Output
6/12V
Input Current
0.48A
Charging Current
4A
Ambient Temperature
-20°C ~ 50°C
Weight
0.66KG
OPERATION
1. Connect the (+) red clamp to the positive (+) battery post and connect the (-) black clamp
to the negative (-) battery pos.
2. Plug the charger into the power supply and switch on and the LCD screen will light up.
3. Press the "MODE button" to select charging program. Settings are made by pressing the "
MODE-button" and stepping forward by pressing the button one step at a time, releasing
the button when the required mode is reached.
4. Stop charging at any time by disconnecting the mains cable from the wall socket.
NOTE: the charger should be connected to the battery before connecting to the mains supply.
To select charging mode or re-set during charging
Mode
0.0
v
Battery voltage
Recon
Battery Repairing
Slow
12V Slow mode:14.4V/1.0A
0.0
v
This mode is normally used for all types of 12V batteries<20Ah
12V
Fast
12V Fast mode: 14.4V/4.0A
0.0
v
This mode is normally used for all types of 12V batteries<80Ah
12V
Winter mode:14.7V/4.0A
0.0
v
This setting is recommended for batteries at temperatures below 5°C.
12V
It is also recommended for many AGM batteries
Mode 7.5V/4.0A
0.0
v
6V
This is normally used for all types of 6V batteries.(Only applies to 9DS311)
Charging Status indicator
FULL
This will show the charging status. When the battery is fully charged,
the word "FULL" will show up
NOTE: This charger has a Memory Function. It will return to last mode you chose, next time the charger is connected.
No.
Description
No.
1
CLAMP CLIP
7
2
UPPER COVER
8
3
BOTTOM COVER
9
4
SEALING RING
10
5
PCB
11
6
CONTROL PCB
customer service e-mail : service@kingtony.com
9DS312
9-Cycle12V
AC 220~240
50/60Hz
12V
0.6A
8A
-20°C ~ 50°C
0.80KG
Description
AC PLUG WITH CABLE
POSITIVE & NEGATIVE CLAMP ASS'Y
SCREW 3x16mm
SCREW 3x12mm
SCREW 3x6mm
899DS31-KT
297x210mm

Publicidad

Tabla de contenido
loading

Resumen de contenidos para King Tony 9DS311

  • Página 1 This setting is recommended for batteries at temperatures below 5°C. It is also recommended for many AGM batteries Mode 7.5V/4.0A This is normally used for all types of 6V batteries.(Only applies to 9DS311) Charging Status indicator FULL This will show the charging status. When the battery is fully charged, WARNING Please wear proper safety gear while working.
  • Página 2 INTELLIGENT AUTOMATIC BATTERY CHARGER INSTRUCTION MANUAL No.9DS31 Enjoy your work...
  • Página 3 SPECIFICATIONS INTRODUCTION • Fully automatic multi-cycle switch mode chargers and maintainers designed for charging a variety of batteries: SLA, WET, AGM/GEL and VRLA. • Chargers will recover slightly sulphated batteries and may rescue drained batteries. • The digital display lets you know exactly how the charger is performing and indicates the charging or maintenance phase and battery voltage.
  • Página 4 OPERATION 1. Connect the (+) red clamp to the positive (+) battery post and connect the (-) black clamp to the negative (-) battery pos. 2. Plug the charger into the power supply and switch on and the LCD screen will light up. 3.
  • Página 5 This setting is recommended for batteries at temperatures below 5°C. Mode 7.5V/4.0A This is normally used for all types of 6V batteries.(Only applies to 9DS311) Charging Status indicator This will show the charging status. When the battery is fully charged, the word “FULL”...
  • Página 6: Fault Codes

    FAULT CODES 1. No clamps connected 2. Short circuit 3. Reverse polarity connection Loose clamps during charging Battery voltage is too high Bad Battery MAINTENANCE • After each use, clean the battery charger clamps be sure to remove any battery fluid that will cause corrosion of the copper clamps.
  • Página 7 WARNING Do not use the product in bathroom or other damp places or places near the water. Do not remodel or dismantle the device.places near the water. Keep the product away from the children. Do not hit or throw the product. Keep the product away from fire.
  • Página 8: Informations Générales

    (AC ou DC), de surchauffe ou d'étincelles. • Affichage numérique indiquant le niveau de charge, la phase de maintenance et la tension de la batterie. Caractéristiques électriques Réf KING TONY 9DS311AAB 9DS312AAB Type 9-Cycle 6/12V 9-Cycle 12V Tension d'entrée...
  • Página 9 MODE D‘EMPLOI 1. Assurez-vous que le chargeur n‘est pas raccordé à la prise secteur. Raccordez en premier le câble plus (+) rouge du chargeur sur le pôle positif de la batterie. Raccordez ensuite le câble moins (-) noir sur le pôle négatif de la batterie.
  • Página 10 Définition des modes affichés : Sélection du mode Mode Indication de la tension Batterie à réparer Programme lent pour batteries 12 V jusqu'à 20Ah. Courant de charge : 1A Tension de charge : 14.4V Programme rapide pour batteries 12 V jusqu'à...
  • Página 11: Code Erreur

    Code erreur 1. Pinces non-connectées 2. court-circuit 3. Inversion de polarité Pince débranchée pendant le chargement Tension batterie élevée Batterie défectueuse Entretien • Nettoyez les pinces après chaque opération de chargement. Éliminez toute projection d‘acide de batterie sur les pinces afin d‘éviter la corrosion. Nettoyez l‘appareil avec précaution à...
  • Página 12 ATTENTION Ne pas utiliser le produit dans une pièce d’eau. Ne pas démonter l’appareil Entreposez le chargeur dans un endroit hors d‘atteinte d‘enfants et de personnes non-autorisées. Ne pas jeter ou frapper sur le produit Entreposez le chargeur dans un endroit non inflammable Ne charger pas l’appareil avec une tension élevée.
  • Página 13: Especificaciones

    ESPECIFICACIONES Informations générales • Los cargadores y aparatos de mantenimiento de ciclo múl- tiple están diseñados para cargar una variedad de baterías: SLA, WET, AGM / GEL y VRLA. • Los cargadores mantienen las baterías ligeramente sulfatadas y podrán arrancar las baterías agotadas. •...
  • Página 14 1. Conectar la (+) pinza roja con el positivo (+) de la batería y conectar la (-) pinza negra con el negativo (-) de la batría. 2. Encender el cargador, se encenderá la pantalla LCD. 3. Pulsar el botón "MODE" button· para elegir el programa. Los ajustes están en "MODE"...
  • Página 15 5'C. Modo 7.5V/4.0A Este modo se usa para todos los tipos de batería 6V (Solo en 9DS311) Indicador de estado de carga. Esto mostrará el estado de carga. Cuando la batería este completamente argada, la palabra "FULL"...
  • Página 16: Códigos De Error

    CÓDIGOS DE ERROR 1. No hay pinzas conectadas 2. Cortocircuito 3. Conexión de polaridad inversa Abrazaderas sueltas durante la carga El valor de la batería es demasiado alto Mala batería MANTENIMIENTO • Después de cada uso, limpie las abrazaderas del cargador de la batería, asegúrese de retirar cualquier líquido de la batería que pueda causar corrosión de las pinzas de cobre.
  • Página 17 ATTENTION No use el producto en el baño u otros lugares húmedos o cerca del agua. No remodelar ni desmontar el dispositivo Mantenga el producto alejado de los niños. No golpee ni lance el producto Mantenga el producto alejado del fuego. No cargue el dispositivo con mayor voltaje.
  • Página 18 Description Description CLAMP CLIP AC PLUG WITH CABLE UPPER COVER POSITIVE & NEGATIVE CLAMP ASS'Y BOTTOM COVER SCREW 3x16mm SEALING RING SCREW 3x12mm SCREW 3x6mm CONTROL PCB...
  • Página 20 www.kingtonyeurope.com www.kingtony.com Customer service e-mail : service-clients@kingtony.eu customer service e-mail : service@kingtony.com 8909DM1371KT 130x90mm...

Este manual también es adecuado para:

9ds312

Tabla de contenido