BEFORE YOU START - GENERAL SAFETY AND INSTALLATION PRECAUTIONS
Please read and understand these instructions fully before you begin this installation and save them for future reference.
The manufacturer will assume no responsibility and the warranty will be void if the user does not adhere to the following
precautions.
Installation Precautions
1) This humidifier will be connected to and used under water pressure and it must be installed in such a way that if a leak occurs,
the water could not cause any damage to the property. Make sure all water connections are properly installed or water spill could
occur.
2) This humidifier is intended for use on forced warm air circulation furnaces, as well as multi-fuel furnaces where temperature does
not exceed 180°F (82ºC). Higher temperatures will damage your humidifier and possibly cause overflow condition and water
damage to your home.
3) Do not install a humidifier where surrounding temperatures may be 32°F (0ºC) or colder. Freezing water will damage
the humidifier and burst the supply pipe, resulting in home damage.
4) Do not install the humidifier or the bypass connection directly on the furnace housing.
5) Do not install the humidifier or the bypass connection on a plenum side where a cooling coil could restrict or inhibit the airflow
through the humidifier.
6) Always check that you are not about to cut or drill into any air conditioning or electrical accessories during installation.
7) Do not install a humidifier on the supply duct where the static pressure exceeds 0.4" Water Column.
8) Do not install a humidifier if the city water pressure exceeds 90 psi. Check the local codes related to pressure reduction.
9) The installation, wiring and plumbing of the humidifier must comply with national and local electrical, plumbing and building
codes.
10) Electrical wiring and water tubing must not come into contact with sharp edges or hot surfaces. For the drainable models, please
make certain the drain tube has no bends, its end placed in a floor drain and there is no resistance to the flow of the discharged
water.
11) The transformer supplied is rated for 120 V power supply. Do not connect it to an installation supplied with another voltage.
12) Do not set the humidity level higher than normally recommended, or condensation damage could occur.
Safety Warnings
1) Please beware of sharp edges when you cut into a metal duct.
2) Always shut the power off before starting the installation. An electric shock from 120 volts could cause injury.