Descargar Imprimir esta página

CarlStahl CSmag Serie Instrucciones De Uso página 8

Imanes elevadores permanentes

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Operating instructions for the
GB
Permanent magnetic lifter CSmag
4. Main factors which influence the lifting capacity of the permanent magnetic lifter
4.1 The thickness and surface quality of the component: before operation, you must deter-
mine what proportion of the component is made from steel. The lifting capacity depends on
the thickness of the component and the lifting capacity curve. If the component's surface
roughness Ra is less than 6.3 μm, there will be no lifter surface gap and the lifting capacity
will be 100%. If the surface roughness Ra is 6.3 μm or above, the lifter surface gap must be
estimated. The air gap lifting capacity curve shown on the performance chart can be used to
determine the lifter's possible lifting capacity as a percentage. The curves can also be found
on either sides of the lifter.
Thickness
Airgap
Thickness
Airgap
Airgap
Airgap
Thickness
Thickness
CS mag -100
CS mag -300
Thickness
Thickness
Airgap
Airgap
Airgap
Airgap
CS mag -1000
CS mag -600
Thickness
Thickness
Thickness
Thickness
Airgap
Airgap
Airgap
Airgap
CS mag -1500
CS mag -2000
Thickness
Thickness
Status: December 2011
8

Publicidad

loading

Este manual también es adecuado para:

Csmag 100Csmag 300Csmag 600Csmag 1000Csmag 1500Csmag 2000