HYDRAULIC SETTINGS THE FIRST TIME THE SYSTEM IS LOADED
KILMA EVO RF CONTROL UNITS WITH L.T. BYPASS KIT
2
1
7
Close the primary H.T. inlet valves (1);
Fully screw the adjustments (2) (3);
Close all L.T. circuits by screwing them (4);
Connect the tap air drain / relief pipe (5); *
Connect the tap system supply pipe (6); *
Open and bleed all the L.T. circuits individually (4);
Close any outlets for H.T. circuits (7)
bathroom furniture, etc.
KILMA EVO RF CONTROL UNITS WITHOUT L.T. BYPASS KIT.
2
1
Close the primary H.T. inlet valves (1);
Fully screw the adjustments (2);
Close all L.T. circuits by screwing them (4);
Connect the tap air drain/relief pipe (5); *
Connect the tap system supply pipe (6); *
Open and bleed all the L.T. circuits individually (4);
* With a quick-coupling fitting. For connections, please refer to the section on "Steps to connect the quick-coupling fitting to the tap" reported here below.
STEPS TO CONNECT THE QUICK-COUPLING FITTING TO THE TAP
Instructions for RBM product IP2028.0-EN_01
4
4
3
5
6
radiators,
4
6
4
5
CLICK
RBM
COLLECTORS WITH L.T. BYPASS KIT
1
Close the inlet valves (1);
Fully screw the adjustments (3);
Close all L.T. circuits by screwing them (4);
Connect the tap air drain / relief pipe (5); *
Connect the tap system supply pipe (6); *
Open and close all the L.T. circuits individually (4);
COLLECTORS WITHOUT L.T. BYPASS KIT
1
Close the inlet valves (1);
Close all L.T. circuits by screwing them (4);
Connect the tap air drain / relief pipe (5); *
Connect the tap system supply pipe (6); *
Open and bleed all the L.T. circuits individually (4);
Open the tap with some turns of key CH18.
This operation is possible also with filling pipe
assembled.
4
4
3
5
6
7
2
4
5
6
3
1
5
6
5
4
6
4
5