Uline H-1784 Guia De Inicio Rapido página 3

Mesa de elevacion de doble tijera
Ocultar thumbs Ver también para H-1784:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

It is very important to conduct necessary maintenance
and upkeep so as to prolong the service life and
safety of the lift table. Please check the lift table before
operation accordingly:
1. Check for any distortion or bending of any parts of
the lift table.
2. Check the brake of the truck and the condition of
the wheels.
3. Check for oil leakage in the hydraulic system.
4. Add or fill lubricant to each friction surface before
daily operation.
OPERATING ISSUE
Does not reach the full lift height.
The table rises then descends.
The table does not descend.
Oil leakage at firing pin.
Oil leakage at pump.
Table will not rise.
Figure 1
Cable
with Boot
PAGE 3 OF 9
MAINTENANCE
5. If there is any failure, the lift table should be repaired
at once before it can be put into use again.
6. Change the hydraulic oil every twelve months,
choose appropriate hydraulic oil according to the
climate conditions.
7. To change the hydraulic oil:
a. Unscrew sealing screw with a wrench.
b. Lift the hand lever (2).
c. Twist off screw of the oil plug and fill pump with
TROUBLESHOOTING
CAUSES
1) Steel ball of the check-valve is not
fully seating.
2) Firing pin does not allow the steel
ball to fully seat.
3) Low hydraulic oil.
1) Steel ball of the check-valve is not
fully seating.
2) Firing pin does not allow the steel
ball to fully seat.
The travel of the firing pin is not enough
to open the steel ball.
The O-ring is damaged.
The seal ring is damaged.
Cable may be disconnected.
Figure 2
Correct
Cable Insertion
1-800-295-5510
uline.com
hydraulic oil.
RECOMMENDATIONS
1) Clean the valve opening and
replace the steel ball.
2) Adjust the tension rate of the steel
wire connecting to the hand lever
to adjust the seating of the firing pin.
3) Add hydraulic oil.
1) Clean the valve opening and
change the steel ball.
2) Adjust the tension rate of the steel
wire connecting to the hand lever
to adjust the seating of firing pin.
Adjust the tension rate of the steel
wire rope to make firing pin at
suitable place and apply lubricant
to the pin.
Change the O-ring.
Change the seal ring.
Ensure cable with silver sleeve
is terminating inside of nut.
(See Figures 1-3)
Figure 3
Incorrect
Cable Insertion
0821 IH-1784

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

H-8152