Common Faults and Troubleshooting
1. In case of jamming or other anomalies during the rotation of the propellers, it's
necessary to cut off the power, take off the top cover of the corresponding
thruster, pull out the propeller, check whether two bearings and propeller are
blocked or entangled, and clear foreign matters adhering to the bearing or
propeller. If not otherwise abnormal, it can be used; if still abnormal, please
contact the after-sales service of the company.
2. In case of accidental damage, bulking or abnormal heating, etc. of the battery,
please stop using and purchase a dedicated battery for replacement.
- 8 -