INSTALLATION INSTRUCTIONS
E-WPT Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
4.
Suitable for operation in ambient not exceeding 40°C.
Peut etre utilise a une temperature ambiante n'excedant
pas 40°C.
5.
Use minimum 75°C supply conductors.
Les fils d'alimentation 75°C min.
6.
SUITABLE FOR MOUNTING WITHIN 1.2m (4ft) OF THE
GROUND
PEUT ETRE INSTALLE A MOINS DE 1,2 m (4 pi) DU
SOL.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
NOTES:
1. Fixture is only intended to be mounted with the light facing
downward. Do NOT mount as an uplight.
2. Fixture is not intended to be dimmed.
www.e-conolight.com
|
LPN00685X0001A0_A
Document:
Created By:
TMT
JUNCTION BOX MOUNTING
NOTE: Slots in mounting plate allow for mounting over 3" or 4"
octagonal junction boxes. Junction box must be at least 1-1/2"
deep for proper installation of fixture.
1.
Loosen the two mounting plate set screws using the supplied Allen
wrench to allow for removal of the mounting plate. Do NOT fully
remove the set screws. See Figure 1.
2.
Route the supply leads from the junction box through the large
center hole in the mounting plate.
3.
Align the slots in the mounting plate with the holes in the junction
box. Attach the mounting plate to the junction box using the
supplied screws. Make sure edge of plate marked "TOP" is
positioned towards the top of the junction box. A high grade
caulking material, such as silicone rubber, should be used
between the gasket on the mounting plate and the mounting
surface to ensure a watertight seal.
4.
Push the (3) supply leads into the inside of the fixture through
the holes in the grommet on the back of the mounting base. See
Figure 2.
NOTE: If the wires from the junction box are not long enough to
push through the holes in the grommet, open the fixture by loosing
the (2) screws on the side and push the grommet out of the
mounting base. Pass the supply leads through the center hole in
the mounting base. Push the supply leads into the grommet holes
from inside the fixture and then plug the grommet back into the
center hole of the mounting base. See Figure 3 on next page.
5.
Hang the mounting base from the mounting plate by positioning
the two angled mounting features on the back of the base over the
upper edge of the plate.
6.
If the fixture was not opened in Step 4, loosen the (2) mounting
base screws on the side to allow the fixture door to swing open.
7.
Complete the electrical connections per the Fixture Wiring
section.
8.
Close the fixture door and re-tighten the (2) mounting base
screws.
FIGURE 1
Allen Wrench
FIGURE 2
Set Screws
888.243.9445
|
FAX: 262.504.5409
3-9-2020
Date
ECO#
011590
Mounting Plate
Set Screws
Mounting
Plate
Grommet on Rear of
Mounting Base
Mounting Base