CABLE CALIBRATION SETTING
Operation:
Step1: Press
to ENTER the CABLE CALIBRATION Submenu.
Step2: Connect the positive and negative clamps together ensuring a solid connection.
Step3: Press the Start/Stop button. The charger will automatically test the output cables.
Settings Displayed:
Important: If the DC output cables need to be replaced, consult your distributor to order a replacement set. Only DC output
cables approved by the manufacturer can be used with this device, once the cables have been replaced, they must be calibrated
as shown above.
LCD BRIGHTNESS SETTING
Operation:
Step1: Press
to ENTER the LCD BRIGHTNESS Submenu
Step2: Press
to Set the desired brightness level.
The default setting is set at 50%.
FIRMWARE UPDATE SETTING
Operation:
Do not attempt to update the Firmware with any other updates than those released by the manufacturer. Critical damage
can occur if unapproved updates are applied or updates are applied incorrectly.
Step1: Download the firmware update onto an empty USB storage device. Connect the storage device to the Charger through
the USB port.
Step2: Press
to Enter the Firmware update submenu
Step3: Press
Step4: Press the Start/Stop button. The device will automatically update the firmware version.
Step5: Once the firmware update is complete, press any key to restart the charger with the updated software.
DEVICE INFORMATION
Operation:
to Enter the Device information display:
Press
Display: Firmware version, the TFT firmware version, the Product rating, etc.