The pressure (BAR) can be switched on or off using the button (16) on the editing display.
7.3.2
Display settings
Press the button (18) on the Home display to access the display settings. The display then changes to the Settings area.
G. Automatic heating function activation / deactivation
When the heating function is activated, the unit heats automatically. The maximum temperature is 70 °C.
If the function is deactivated, the device heats up to the corresponding target temperature only after a
program is selected.
H. Water draining program
The casting unit can be manually pressurized with compressed air to drain contaminated water via the water
drain valve. Switching on / off is done by pressing repeatedly. If the program is selected, all heating functions
are deactivated.
I.
Dimmer function activation / deactivation
When the function is activated, the screen automatically dims after 2 minutes of no operation. After pressing
a button, the screen lights up again. When the function is deactivated, the brightness of the screen does not
change.
J.
Changing the temperature unit (°C / °F)
7.3.3
Start & pause a process
Press one of the buttons (15 / 16 / 17) on the Home display to select the corresponding program. The corresponding polymeri-
sation settings (temperature / time / pressure) can be read on the program display. The program starts when the button (18) is
pressed. The current temperature is shown in the middle of the display. The arrow to the left of the symbol indicates "heating
or "cooling ". The timer starts automatically when the target temperature is reached.
When the pressurization process (BAR) is activated, compressed air begins to flow immediately after the process has started.
The pressure pot is then pressurized with 2 bar. The Pressure screen (4) provides an additional check.
After the timer has expired, the compressed air is released automatically and an audible beep sounds. There is danger of scalding
in the vicinity where the pressure is released! The end of the program is also indicated when the timer has run down to 0:00.
Press the button (18) to pause the program.
The timer stops, the temperature is maintained and the pressure is switched off.
There is danger of scalding in the vicinity where the pressure is released!
This function is used to remove and add objects to the pot during a program run.
Polymerization unit for hot- and cold-curing resins
Pressure
Pressure ON
Display settings
G
I
Program display
Operating Instructions
Pressure OFF
H
J
18
GB
- 9 -
"