Descargar Imprimir esta página

E2S MA1 Serie Guia De Inicio Rapido

Publicidad

Enlaces rápidos

INSTRUCTION & SERVICE MANUAL
MA1 & MA2 M Range Sounders
IP67/66 & Type 4/4X/13
-40°C to +66°C (-40°F to +151°F)
DC: 2.5Kg (5.5lb); AC: 3.0Kg (6.5lb)
CE, EAC & Russian Maritime Register
approved
Nominal
Nominal
Unit Type
Nominal
Voltage
Current
Current
Code
Voltage
Range
P1 (mA)
P2 (mA)
MA1RDC024
280/
224/122
MA1FDC024
12 Vdc /
10-
376/391/
24 Vdc /
MA2FDC024
60Vdc
§
223
48Vdc
376/391/
MA2HDC024
223
MA1RAC230
115
100/64
100 -
MA1FAC230
Vac /
240Vac
MA2FAC230
173/107
230 Vac
50/60Hz
50/60Hz
MA2HAC230
173/107
*Max = Tone 4 /
Nom. = Tone 44 /
x̄ = Average over 64 tones /
5mm
0.5 2.5mm
Use suitable conduit or cable glands
with suitable IP or type rating
Attention
: Installation must be carried out by an electrician in compliance with the latest codes and regulations.
Attention
: L'installation doit être effectuée par un électricien conformément aux derniers codes et réglementations.
Achtung
: Die Installation muss von einem Elektriker gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden.
Attenzione
: L'installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti.
Atención
: La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones.
Atenção:
A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes.
Внимание
: установка должна выполняться электриком в соответствии с последними нормами и правилами .
Attention
: Disconnect from power source before installation or service to prevent electric shock
Attention
: Débranchez-le de la source d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique.
Achtung
: Vor Installation oder Wartung von der Stromquelle trennen, um einen Stromschlag zu vermeiden.
Attenzione
: scollegare dall'alimentazione prima dell'installazione o dell'assistenza per evitare scosse elettriche.
Atención
: desconéctelo de la fuente de alimentación antes de la instalación o el servicio para evitar descargas eléctricas.
Atenção:
Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico
Внимание
: отключите от источника питания перед установкой или обслуживанием , чтобы предотвратить поражение электрическим током.
E2S Warning Signals
Impress House, Mansell Road, Acton, London W3 7QH
MA1R
MA1F
MA2F
Sound Pressure Level
Sound Pressure
Nominal
P1, dB(A)
Level P2, dB(A)
Current
P3 (mA)
Max*
Nom
.†
Max*
Nom
.†
113.6
110.7
109.7
116.6
113.7
112.7
440/888/
120.0
116.6
114.7
453
440/888/
125.3
122.5
120.1
§
453
113.6
110.7
109.7
116.6
113.7
112.7
§
340/212
120.0
116.6
114.7
§
340/212
125.3
122.5
120.1
§
Denotes factory P2/P3 setting
0.4Nm
sales@e2s.com
e2s.com
AC
See D207-06-001
L/+
L/+
N/-
N/-
MA2H
E
C
S2
S3
Sound Pressure
Level P3, dB(A)
Max*
Nom
.†
S2
DC
123.4
120.1
118.0
See D207-06-005
128.6
125.9
123.1
123.4
120.1
118.0
+
128.6
125.9
123.1
+
-
-
S2
S3
(DC Only, see D207-06-001)
+ve switching
(Default)
H1
H2
ve switching
H1
H2
Link W1
Page 1 of 2
S1
S2
S1
(AC & DC, see D221-95-001)
Default = S2 - Tone 1
P1
P2
P3
P1
P2
P3
Default = S1 - Tone 44
(ON = 1, OFF = 0)
D207-00-001-IS_Issue_3 - 12/03/2021

Publicidad

loading

Resumen de contenidos para E2S MA1 Serie

  • Página 1 Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico Внимание : отключите от источника питания перед установкой или обслуживанием , чтобы предотвратить поражение электрическим током. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com e2s.com...
  • Página 2 MA[X][F][VOLT][ MA1R, MA1F, MA2F MA[X][F][VOLT][ 1/2” NPT 1/2”NPT 4 OFF POS'NS 3 OFF POS'NS ∠ MA1R, MA1F, MA2F MA2H MA2H E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH sales@e2s.com e2s.com Page 2 of 2 D207-00-001-IS_Issue_3 - 12/03/2021...

Este manual también es adecuado para:

Ma2 m serieMa1rdc024Ma1fdc024Ma2fdc024Ma2hdc024Ma1rac230 ... Mostrar todo