Specifications
Output Specifications
Outputs
4 SPST relays
Contact ratings (AgSnO2)
µ (micro gap)
Resistive loads
AC1
20 A
In-rush current
120 A (20 msec.)
Max. switching voltage
440 VAC
Max. switching power
10 kVA
Capacitive load
≤ 200 µF
Lamp load
≤ 4800 W
Switching operations
≥ 60000 operations
Minimum load
100 mA/12 V
Max. Switching Frequency
2 Hz
Response time
≤ 1 pulse train
Supply Specifications
Power Supply
Overvoltage cat. III
(IEC 60664)
Rated operational voltage
Through term. 21 & 22
230 VAC, +/- 10%
(IEC 60038)
Frequency
45 to 65 Hz
Rated operational power
Typ. 2,5 VA
Max. power dissipation
7 W
Rated impulse withstand volt.
230
4 kV
Dielectric voltage
Supply – smart-house
≥ 4 kVAC (rms)
Supply – Outputs
≥ 4 kVAC (rms)
Outputs – smart-house
≥ 4 kVAC (rms)
General Specifications
Fail polarity state delay
Upon loss of smart-house carrier ≤ 20 ms
Power ON delay
typ. 2s
Indication for:
Supply ON
LED, Green
smart-house carrier
LED, Yellow
Output ON
LED, Red (one per output)
Environment
Degree of protection
IP 20
Pollution degree
3 (IEC 60664)
Operating temperature
-
5 to +50°C (+23° to +122°F)
Storage temperature
-50 to +85°C (-58° to
+185°F)
Humidity (non-condensing)
20 to 80%
Mechanical resistance
Shock
5 G (11ms)
Vibration
2 G (6 to 55Hz)
Housing
H8-housing
Weight
500 g
Mode of Operation
4-channel receiver with 4 normally open contact outputs. Each
output is individually coded by means of the code programmer
BGP-COD-BAT. For changing the default setting, please refer to
the datasheet on BGP-COD-BAT.
The outputs are normally OFF. When a transmitter coded to the
selected channel is activated, the output turns ON and remains
ON until the respective channel becomes deactivated. The
default setting is such that upon loss of smart-house carrier, all
the outputs go OFF. If fail polarity is set to 1, the relays will go
on upon loss of carrier.
On the front of the module, it is possible to override each relay
mechanically. The LEDs will not follow manual override. The
manual override will be reset if smart-house or power is put
off and on in min. 10 seconds. Each relay is labled so that it is
possible to see the relay's actual status.
Note: At delivery some of the relays might be ON due to trans-
portation bumps. To be sure that the relays are OFF, connect
the module to power and smart-house and transmit on chan-
nels A1-4 once.
Note: Due to the construction with bistable relays, the
module is intended for heating and light control only.
Dimensions
Dimensiones / Dimensjoner
Wiring Diagram
Diagrama de conexiones / Koblingsskjema
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
2
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
out
out
1
2
Power
supply
User Manual
Manual del Usario
Brukerveiledning
Over Hadstenvej 40, DK-8370 Hadsten
Phone +45 89606100, Fax +45 86982522
D+
D-
3
4
out
out
3
4
Output Module 4 x 20 mp
BH8-RE20 4-230
Módulo de salida 4 x 20 amperios /
Utgangsmodul 4 x 20 mp
ertified in accordance with ISO 9001
Empresa que cumple con ISO 9001
Sertifisert i henhold til ISO 9001
MAN BH8-RE20A4-230 rev 15 09.2009

Publicidad

loading

Resumen de contenidos para SMART-HOUSE BH8-RE20A4-230

  • Página 1 On the front of the module, it is possible to override each relay Specifications mechanically. The LEDs will not follow manual override. The manual override will be reset if smart-house or power is put off and on in min. 10 seconds. Each relay is labled so that it is Output Specifications...
  • Página 2 Hver utgang kodes individuelt ved hjelp av kodeprogrammer- Impulso de tensión soportada y al smart-house y realice una sola transmisión en los canales ingsenheten BGP-COD-BAT. Endringer av standardinnstilling 4 kV A1 a A4.