Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

®
Overview
The Multi-Unit Gate Access Panel (MUGAPLM) uses
a digitally secure intercom link that allows it to control
up to four gate operators and other accessories. It
can be used with up to 63 homes and program up to
120 remote control transmitters.
The MUGAPLM is compatible with various LiftMaster
Wireless Products.
Carton Inventory
Multi-Unit Gate Access Panel (MUGAPLM)
Key (2)
Accessory Overview
Telephone Interface Unit (OTIU): The
OTIU allows the user to identify which
gate or door a visitor is at with Caller ID
and a distinctive ring tone. To answer a
call press "0". A gate can be opened by
dialing "*9" on the telephone keypad.
Multi-Unit Telephone Interface
(MUOTIU): The MUOTIU acts as a
wireless remote autodialer in a dedicated
line system.
Portable Intercom: The intercom allows
the user to speak with visitors at the
MUGAPLM and open the gate by holding
the Remote button for 10 seconds.
Flush Mount Intercom: The intercom
allows the user to speak with visitors at
the MUGAPLM.
Repeater Set: Repeaters are used to
extend the range between the
MUGAPLM and other devices. They are
recommended for use with buildings with
stucco or cement walls.
Remote Control Transmitter: The
remote control transmitter will open the
gate when the numbered button is held
down for 5 seconds within 75' of the
MUGAPLM.
MUGAPLM Installation &
Assembly
Step 1
Choose mounting location for MUGAPLM. Remove
the back panel and attach it to a solid surface or post.
Step 2
Bolt (4)
Washer (4)
Install 4 C batteries (not provided) in the MUGAPLM
Nut (4)
and it will beep until the Master PIN Number is
entered.
NOTE: To prevent damage to the circuit DO NOT use
C size Lithium batteries or rechargeable batteries. If
Lithium batteries are needed, switch the C battery
pack with the provided AA battery pack.
Step 3
On keypad press:
Step 4
Enter 4 digit Master PIN Number. Example: 1234.
NOTE: " * " is a cancel button that will cancel any call
or key sequence.
Step 5
Mount the MUGAPLM onto the back panel. Lock
MUGAPLM with key.
NOTE: Do not slam the MUGAPLM against the wall
or the temper sensor will activate.
If additional MUGAPLM is being used see Operation
& Features: Multi-GAP Mode.
1
Model MUGAPLM
Multi-Unit Gate Access Panel
#
#
#
?
?
?
?
"BEEP" "BEEP"

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Chamberlain LiftMaster Professional SECURITY+ MUGAPLM

  • Página 1 Model MUGAPLM Multi-Unit Gate Access Panel ® MUGAPLM Installation & Assembly Overview Step 1 The Multi-Unit Gate Access Panel (MUGAPLM) uses a digitally secure intercom link that allows it to control up to four gate operators and other accessories. It can be used with up to 63 homes and program up to 120 remote control transmitters.
  • Página 2 NOTE: If there is already an existing receiver proceed to Pre-Installed LiftMaster Receiver Within 20 seconds enter Master PIN Number on (315Mhz Only) section. MUGAPLM: Gate Control Unit (GCU) (not provided) Followed by GCU Identity as determined in Step 3: Assemble Step 1: Remove GCU cover.
  • Página 3 Pre-Installed LiftMaster Programming Accessories Receiver (315Mhz Only) Indoor Multi-Unit Telephone Interface Program (MUOTIU) Indicator Light Step 1: Pry open the front Learn Button panel of the receiver case with a coin or a screwdriver. Step 2: Press and release the Learn button on the receiver.
  • Página 4: Remote Control Transmitter

    Repeater Set Remote Control Transmitter Step 1: On ONE repeater, set Dipswitch #1 to ON. All Each numbered button on a remote control other Dipswitches should remain OFF. transmitter must be programmed separately as each Step 2: Press Learn button on both Repeaters (within button controls one of four GCU’s.
  • Página 5 Operation & Features Change Master PIN Number Adding PIN Numbers Enter Master PIN Number on MUGAPLM: The MUGAPLM can support up to 99 PIN Numbers. Enter Master PIN Number on MUGAPLM: “BEEP” “BEEP” Enter new Master PIN Number: Enter new PIN Number: “BEEP”...
  • Página 6: Vacation Mode

    Multi-GAP Mode Alternate Channel Selections The MUGAPLM can be set to Passive Mode to work The MUGAPLM can be set to one of three channels to with multiple MUGAPLM’s. The Passive MUGAPLM will prevent range-reducing interference from conflicting become an accessory to the Active MUGAPLM. Any radio transmitters.
  • Página 7 Multi-GAP Default GCU Setting Battery The Passive MUGAPLM defaults to activating GCU #2 The AA batteries (not provided) in the GCU will last when it is activated by a PIN Number entered on that up to a year and a half depending on use (Lithium keypad, a near-by Remote Control Transmitter, or if the batteries recommended for colder environments.) If Call button is pressed.
  • Página 8 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. © 2009, The Chamberlain Group Inc. 114A3890...
  • Página 9: Descripción General

    Modelo MUGAPLM Panel de acceso a la puerta de unidades múltiples ® Instalación y montaje del Descripción general MUGAPLM El Panel de acceso a la puerta de unidades múltiples (MUGAPLM) usa un enlace de intercomunicador que Paso 1 permite controlar hasta cuatro operadores de puerta y otros accesorios.
  • Página 10: Instalación

    NOTA: Si ya hay un receptor existente, pase a la sección Receptor LiftMaster preinstalado (sólo 315 Mhz). En menos de 20 segundos, ingrese el número de PIN principal en el MUGAPLM: Unidad de control de puerta (GCU) (no incluidas). Luego ingrese la identificación de la GCU, como se Montaje determina en el Paso 3: Paso 1: Retire la cubierta de...
  • Página 11: Receptor Liftmaster Preinstalado (Sólo 315 Mhz) Programación

    Receptor LiftMaster preinstalado Programación de accesorios (sólo 315 Mhz) Interfaz de teléfono interior con unidades múltiples (MUOTIU) Programación Luz indicadora Paso 1: Abra el panel delantero Botón “Aprendizaje” de la caja del receptor con una moneda o un destornillador. Paso 2: Presione y suelte el botón Aprendizaje del receptor.
  • Página 12: Juego De Repetidores

    Juego de repetidores Transmisor de control remoto Cada botón numerado en un transmisor de control remoto Paso 1: En UN repetidor, configure el conmutador DIP N.º 1 se debe programar en forma separada, ya que cada botón en ENCENDIDO. Todos los demás interruptores DIP deben controla una de las GCU.
  • Página 13: Características Y Operación Agregar Números De Pin

    Características y operación Cambie el número de PIN principal Agregar números de PIN Ingrese el número de PIN principal en el MUGAPLM: El MUGAPLM puede tener hasta 99 números de PIN. Ingrese el número de PIN Principal en el MUGAPLM: “BEEP”...
  • Página 14: Alternar Selecciones De Canales

    Modo GAP múltiple Alternar selecciones de canales El MUGAPLM se puede configurar en el modo Pasivo para El MUGAPLM se puede configurar en uno de tres canales para trabajar con múltiples MUGAPLM. El MUGAPLM pasivo se evitar que la interferencia que reduce el alcance entre en convertirá...
  • Página 15: Configuración De Gcu Predeterminada De Gap Múltiple

    Configuración de GCU predeterminada de Batería GAP múltiple Las baterías AA (no incluidas) en la GCU durarán hasta un año y medio dependiendo del uso (se recomiendan las El MUGAPLM pasivo está predeterminado para activar la GCU baterías de litio para ambientes más fríos). Si las baterías N.º...
  • Página 16: Resolución De Problemas

    Se ha probado para cumplir con las NORMAS DE LA FCC PARA USO EN EL HOGAR O LA OFICINA. La operación está sujeta a las dos condiciones siguientes:(1) este dispositivo no puede causar interferencia perjudicial, y (2) este dispositivo debe aceptar cualquier interferencia recibida, incluyendo la interferencia que puede causar una operación no deseable. © 2009, The Chamberlain Group Inc. 114A3890 Todos los derechos reservados...

Tabla de contenido