Konig Computer CMP-BARSCAN10 Manual Del Usuario página 4

Tabla de contenido

Publicidad

Barcode Scanner Setup Procedures
1)
Locate a group that contains the parameters
to be changed.
2)
Scan the "Enter Group #" label. The scanner
will beep to indicate that setup is in progress.
3)
Scan the label representing the parameter to
be changed.
4)
Scan the "Exit" label to exit the group
currently selected. The scanner will beep.
5)
Repeat the procedure for other groups
including the parameters to be changed.
Example 1:
Set the operating mode to "Continuous mode"
1)
Scan "Enter Group 5"
2)
Scan "Continuous/Trigger off"
3)
Scan "Exit"
Example 2:
Assign Preamble string as "#", and Postamble string
as "END"
1)
Scan "Enter Group 6".
2)
Scan Preamble.
3)
Scan "#" from "Full ASCII Table and Table-
Hex.".
4)
Scan "Confirm" Label in Table-Hex.
5)
Scan "Postamble".
6)
Scan "E", "N", "D" from "Full ASCII Table" and
"Table Hex" consecutively.
7)
Scan "Confirm" Label in Table-Hex.
8)
Scan Exit.
2

Publicidad

Tabla de contenido
loading

Tabla de contenido