TECHNICAL DATA

Production code .......................................................................................................
Rate of air fl ow .........................................................................................................
Vacuum ....................................................................................................................
Dry capacity .............................................................................................................
Wet capacity ............................................................................................................
Filter surface / Hepa fi lter type ................................................................................
Suction hose diameter .............................................................................................
Suction hose length .................................................................................................
Battery voltage .........................................................................................................
Length/width/height .................................................................................................
Weight according EPTA-Procedure 01/2014 (with battery 6.0 Ah) ........................
Protection class .......................................................................................................
Recommended ambient operating temperature ....................................................
Recommended battery types ..................................................................................
Recommended charger...........................................................................................
Noise/vibration information
Measured values determined according to ISO 4871.
Typically, the A-weighted noise levels of the tool are:
Sound power level (Uncertainty K=2 dB(A)) .......................................................
Sound pressure level (Uncertainty K=2 dB(A)) ..................................................
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined according to
EN 60335-2-69.
Vibration emission value a
.................................................................................
h
Uncertainty K ........................................................................................................
WARNING Read all safety warnings, instructions, illustrations
and specifi cations provided with this power tool. Failure to follow all
instructions listed below may result in electric shock, fi re and/or serious
injury.
Save all warnings and instructions for future reference.
WARNING: Operators shall be adequately instructed on the use of
these machines.

SAFETY INSTRUCTIONS

This machine is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge. Children should be supervised to ensure that they do not
play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
This appliance may only be operated under supervision.
Fire and explosion hazard!
Never suck up into the machine any infl ammable or explosive solvents, or
liquids like petrol, oil, alcohol, thinners, or small particles (such as metal
fi lings or ash) that may be hotter than 60°C - otherwise there is danger of
explosion or fi re!
WARNING If foam or liquid escapes from the machine, switch off
immediately.
You are not allowed to use the appliance in the vicinity of infl ammable
gases or substances.
Do not point the nozzle, hose or tube at people or animals.
Keep hair, loose clothing, fi ngers and all parts of the body away from
ope nings and moving parts. Do not put any objects into openings or use
with opening blocked. Keep openings free of dust, lint, hair, and anything
else that could re du ce the fl ow of air.
Warning! To reduce the risk of fi re, personal injury, and product damage
due to a short circuit, never immerse your tool, battery pack or charger in
fl uid or allow a fl uid to fl ow inside them. Corrosive or conductive fl uids,
such as seawater, certain industrial chemicals, and bleach or bleach
containing products, etc., can cause a short circuit.
Never break open battery packs and chargers and store only in dry
rooms. Keep dry at all times.
Use only System M12 chargers for charging System M12 battery packs.
Do not use battery packs from other systems.
Before starting work, the operating staff must be informed on and trained
within:
• use of the machine
• risks associated with the material to be picked up
22
ENGLISH
470 444 - M12FVCL.indd 22
470 444 - M12FVCL.indd 22
CORDLESS VACUUM CLEANER
M12 FVCL
..................... 4776 48 01...
...000001-999999
...................... 1275 l/min (76 m
3
/h)
........................105 mbar (105 hPa)
................................5,68 l
................................6,06 l
......................HEPA H13
................................... 41 mm
.................................475 mm
................................... 12 V
...................348/220/302 mm
..................................... 5 kg
................................IP54
.........................-18...+50 °C
..........................M12B...
............ C12C, M12C4, M12-18...
.................................88,0 dB (A)
.................................76,0 dB (A)
...................................0,1 m/s
2
...................................0,5 m/s
2
• safe disposal of the picked up material
The following materials must not be picked up by the machine:
• hazardous dusts which belong to the classes M and H
• hot materials (burning cigarettes, hot ash, etc.)
• fl ammable, explosive, aggressive liquids (e.g. petrol, solvents, acids,
alkalis, etc.)
• fl ammable, explosive dust (e.g. magnesium or aluminium dust, etc.)
For Dust Class L machines (with type designation -0L, -2L) following
applies:
• The appliance is suitable for picking up dry, non-fl ammable dust and
liquids, hazardous dusts with
OEL
value > 1 mg/m³.
1)
• Dust Class L (IEC 60335-2-69).
• The dusts which belong to this class have OEL
• For machines intended for the Dust Class L, the fi lter material is tested.
The maximum degree of permeability is 1% and there is no special
requirement for disposal.
• For dust extractors, ensure adequate air change rate L, when the
exhaust air is returned to the room. Observe national regulations before
use.
Besides the operating instructions and the binding accident prevention
regulations valid in the country of use, observe recognised regulations for
safety and proper use.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
Any other use is considered as improper use. The manufacturer accepts
no liability for any damage resulting from such use. The risk for such use
is borne solely by the user. Proper use also includes proper operation,
servicing and repairs as specifi ed by the manufacturer.

SPECIFIED CONDITIONS OF USE

This mobile dust extractor is designed, developed and rigorously tested to
function effi ciently and safely when properly maintained and used in
accordance with the following instructions.
This machine is intended for commercial use, for example in hotels,
schools, hospitals, factories, shops, offi ces and rental businesses.