ADDITIONAL SAFETY WALL PAPER STEAMER
• Ensure boiler is placed on a flat level surface
and should the boiler become tilted in use level
again immediately. Failure to do so can result
in severe overheating, complete element failure
and void of your guarantee.
• Block boiler unit securely if using on stairs
• The boiler becomes hot in use, move only by
using the carrying handle.
• Steam is produced at 100°C be careful, wear
protective clothing and protect your hands with
heat resistant gloves or mitts.
• Never point hose or steam plate at anyone.
• Always keep steam plate tilted away from face
and body, beware of hot drips and regularly
empty collected condensation from plate – es-
pecially when stripping ceilings and high areas.
• Never remove elbow filler cap or detach hose
whilst unit is operating.
• Never block the safety valves on the top of the
boiler.
• Do not overfill the reservoir.
• Allow to cool completely before emptying boiler.
• Do not stan on boiler of hose.
• So not drag or try to move the boiler by pulling
the mains lead.
• Do not allow water or steam to enter light swit-
ches or power points.
• Do not leave unattended.
• Use only standard tap water, never add deter-
gents of chemicals.
• Extreme care must be taken if the unit is used in
bathrooms. Always be aware of danger of elec-
trocution from stored water in baths and sinks.
• It is recommended that a RCD (residual current
device) Rated at 30mA is fitted into the mains
supply socket for added protection against
electric shock.
• The appliance must be unplugged after use
and before cleaning of user maintenance of the
appliance.
• Do not remove the filler cap while the unit is
operating. Switch off and allow the appliance to
cool for 2 minutes before removing the cap to
refill boiler.
• Do not leave the unit unattended when switched
on.
• Liquid or steam must not be directed towards
equipment containing electrical components.
• Never submerge the unit in water or other
liquids or pour water over the unit.
6
• Never overfill the water tank past the MAX indi-
cator (maximum 4,5 litres).
• Make sure that the boiler is placed on a safe and
flat surface. Do not tip the boiler as there is a
risk of water entering the hose.
• Keep the cable away from heat and sharp edges.
• Do not place the boiler higher than ground level
e.g. on a step ladder or table.
• The boiler and the steam plate become hot
during use. Always hold the steam plate and the
boiler by the handles provided.
• Never detach the hose while the unit is switched
on. Allow to cool down for 10 minutes.
• Do not allow the hose to become kinked or bloc-
ked by de¬bris. In the event of a hose blockage
remove the plug from the wall socket.
Electrical safety
Always check that the voltage of the power
supply corresponds to the voltage on the
rating plate label.
• Do not use the machine if the mains cable or
the mains plug is damaged.
• Only use extension cables that are suitable for
the power rating of the machine with a minimum
thickness of 1.5 mm
. If you use an extension
2
cable reel, always fully unroll the cable.

2. MACHINE INFORMATION

Intended use
The wall paper steamer is developed for stripping
wall paper. The steam helps removing wall paper
without chemicals. This machine converts water
into steam.

TECHNICAL SPECIFICATIONS

Model No.
Voltage
Input power
Boiler Capacity
Weight
Tube length
Tube diameter
Steam plate dimensions
Working time (4.5L)
WS501AC
230-240V 50Hz
2000W
4.5 L
2 kg
350 cm
24 mm
270x190mm
75 min