Electrical Connections; General Information - FCI Home Appliances ECCB 30 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DANGER
Disconnect power before servicing the
product. Failure to do so could result in death
or electrical shock.

General information

This cooktop does not require a neutral connection. If
the cooktop is to be completely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Figure 13. Location of serial tag
Connect with copper wire only
If the house has aluminum wiring, follow the
procedure below:
1. Connect the aluminum wiring to the copper wire
by using special connectors designed and
Underwriters Laboratories-listed for joining copper
to aluminum. Follow the electrical connector
manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with
local codes and industry- accepted wiring
practices.
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly to junction box. Do not
cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
12
Models ECCB/TCCB 30" – 36"

Electrical Connections

supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
Improper connection of aluminum house wiring to
the copper leads can result in a serious problem.
30"
36"
*Digits identifying color cooktop
Batter/march Park Quincy, Massachusetts 02269
A three-wire, single phase, 240 volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the
electrical wiring and hookup be accomplished by a
competent electrician.
Installation Manual
WARNING
Model
Power
TCCB 33052/**
TCCB 33053/**
TCCB 33066/**
TCCB 33067/**
240 V 28 A
6.7 kW
ECCB 33050/**
ECCB 33051/**
ECCB 33070/**
ECCB 33071/**
TCCB 33656/**
TCCB 33657/**
240 V 32 A
7.6 kW
TCCB 33668/**
TCCB 33669/**
ECCB 33654/**
ECCB 33655/**
240 V 39 A
9.4 kW
ECCB 33674/**
ECCB 33675/**
National Fire Protection Association
ENGLISH
Required
Minimum
power
supply wire
supply
size
No.
60 Hz
10AWG
No.
60 Hz
10AWG
No.
60 Hz
10AWG

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eccb 36Tccb 30Tccb 36

Tabla de contenido