Overheating
If the temperature limiter has been triggered due to overheating,
reset as follows:
• Disconnect the electricity with the all-pole switch.
• Investigate the matter and repair the fault.
• Reset by opening the lid and pushing the red
button on top of the temperature limiter until a
click sound is heard.
• Put on the lid and reconnect the heater.
Maintenance
The motor and other components are maintenance-free. Dust
and dirt may cause overheating and danger of fire. The appliance
must therefore be cleaned regularly.

Technical data

Type
Output
[kW]
Voltage
Current
Output staging
[kW]
Airflow half output
[m³/h]
Airflow full output
[m³/h]
Temperature rise
Sound level
[dB(A)]
2)
Weight
Protection class
SE 135 connected 440V 3~ => Output 0 / 5,15 / 10,3 kW ; Current 13,4 A ; Temperature rise 34/24 °C
1)
Sound level in distance of 3 m, Q =2, Absorption area = 200 m² Sabine, Tolerance ± 2 dB
2)
Accessories
Control panel
External one-stage thermostat
External two-stage thermostat
Automatic temperature regulator
Damper and automatic temperature regulator
Mixing cabinet
Damper motor
Control lever
Air director
Ventilation fan 1400 m³/h
Timer 1/2-1-2-4h alt. 4-8-16-24h
Load guard 16 – 35 A
Current transformer 67 - 145 A
Drying room kit
Ceiling fan
Panther 6 - 15 kW
SE06
6
[V]
230V 3~/
400V 3N~
[A]
15,1/8,7
0 / 3 / 6
900
1300
[°C]
20 / 14
39 / 47
[kg]
21
IP 44

Safety cut-out

If the installation is protected by means of a safety cut-out,
which trips when the appliance is connected, this may be due to
moisture in the heating element. When an appliance containing a
heater element, has not been used for a long period and is stored
in a damp environment, moisture can enter the element. This
should not be seen as a fault, but is simply rectified by connecting
the appliance to the mains supply via a socket without a safety
cut-out so that the moisture can be driven out of the element.
The drying time can vary from a few hours to a few days. As a
preventive measure the fan heater should occasionally be run for
a short time when the heater is not being used for an extended
period of time.
SE09
9
230V 3~/
400V 3N~
22,6,/13
0 / 4,5 / 9
900
1300
30 / 21
39 / 47
22
IP 44
Code
PP15
KRT 1900
KRT 2800
PTA01
PSA01
PBS01
PSM01
PHR01
PLR15
PFF15
CBT
FEV01
FEVS02
PTRP
ICF20/ICF55
SE12
SE15
12
15
230V 3~/
230V 3~/
400V 3N~
400V 3N~
30,2/17,3
37,7/21,7
0 / 6 / 12
0 / 7,5 / 15
900
900
1300
1300
40 / 28
50 / 35
39 / 47
39 / 47
22
22
IP 44
IP 44
GB
SE135
13,5
500V 3~
1)
15,6
0 / 6,75 / 13,5
900
1300
45 / 31
39 / 47
23
IP 44
CBT
FEV01
PTRP
ICF20/ICF55
9