insTALLATion of LuBricATor
1. Maximum air pressure to unit is 140 PSIG (9.7 BAR).
2. Mount the unit as close to the item to be protected as possible.
3. Direction of air flow is designated by an " " and " " on the
primary unit.
4. Ensure that a Filter/Regulator installation is complete BEFORE
installing the Lubricator.
5. Use ISO-VG32 or similar lubricant.
6. Add lubricant into the oil bowl (#2) through the fill plug (#11)
opening. Unscrew the fill plug by turning counterclockwise.
Do not fill past "Max Oil Level" line indicated on the outside of
shatterguard. After filling the oil bowl, replace the oil fill plug
securely.
7. During operation, air flow does not have to be shut off to add
lubricant. Lubricant can be added any time by using the oil fill plug
as noted above.
WARNING!
Pressure systems can leak causing flying particles.
Wear safety goggles. (User and bystanders).
Read and follow instructions.
Flying particles can cause injury.
Compressor systems contain air under pressure that can create
a high pressure stream.
Relieve pressure before servicing.
A pressurized air stream can cause injury.
WARNING: NEVER REMOVE THE BOWL TO ADD
LUBRICANT. ALWAYS USE FILL PLUG OPENING.
reguLATing oiL drop
1. To regulate the amount of oil dropped during air flow,
use adjusting screw (#10) on top of Lubricator. Turn screw
counterclockwise for more oil and clockwise for less oil. NOTE:
After setting the desired oil drop using the adjusting screw, be
aware that as air flow is regulated up or down, the oil drop will
be changed also. More air flow will increase oil drop and less air
flow will decrease oil drop.
MAinTenAnce
1. Before preforming any maintenance on this unit, shut off the
air supply to the unit and completely discharge all air until no air
pressure exists in the unit. Avoid breathing any discharged air
directly.
WARNING: A PRESSURIZED STREAM OF AIR
CAN CAUSE SERIOUS INJURY!
2. Unscrew shatterguard counterclockwise and remove, being
careful not to lose the O-Ring (#5).
AL22
AL22 LUBRICATOR UNIT
3. Clean the transparent bowl (#2) with a clean, dry cloth. Do not
use any chemical that might damage the bowl material. When
reassembling, be sure the O-ring is in the proper position and the
shatterguard is securely tightened.
4. Be advised that the plastic parts could show signs of premature
aging and discoloration if exposed to paints, inferior grade
lubricants, detergents or other chemicals.
OTHER FLUIDS, ESPECIALLY FLAMMABLE LIQUIDS SUCH AS
GASOLINE OR ALCOHOL. SERIOUS DAMAGE OR INJURY TO THE
USER COULD RESULT.
WArrAnTy
Matco® air tool accessories are warranted against defects in
materials or workmanship for a period of 1 year from original
purchase. We will repair or replace at our option any defective part
or unit which proves to be defective in material or workmanship
within this warranty plan. This warranty does not cover damage
to accessories arising from alteration, abuse or misuse, and does
not cover any repairs or replacement made by anyone other than
Matco or its authorized service centers.
The foregoing obligation is Matco Tools sole liability under this
or any implied warranty and under no circumstances shall we be
liable for any incidental or consequential damages.
NOTE: Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
Return air tool accessories to Matco Tools transportation prepaid.
Be certain to include your name and address, evidence of the
purchase date, and description of the suspected defect.
If you have any questions about warranty service, please write
to Matco Tools, Stow, OH 44224. This warranty gives you specific
legal rights and you may also have other rights which vary from
state to state.
3
WARNING: THIS UNIT IS NOT TO BE USED WITH ANY
05/15/12